Page MODEL 761WHNTDECORATIVE VENTILATIONfAN WITH LIgHTREAD AND SAVE THESE INSTRUCTIONSTYPICAL INSTALLATIONSHOUSINGMOUNTING TABSPOWER CABLEGRILLEPANGLASSLIGHT SHADECEILINGJOISTCEILINGMATERIALHOUSINGHOUSINg MOUNTEDDIRECTLY TO jOIST2x6 (or larger)Discharge parallel to joists.HOUSING2 x 4CEILINGJOIST orTRUSSMOUNTINGTABSPOWER CABLE ADDITIONALFRAMING2 x 4CEILINGJOIST orTRUSSCEILINGMATERIALGRILLEPANGLASSLIGHT SHADEHOUSINg MOUNTEDTO 2x4 TRUSSRequires additional framingfor mounting tabs.Discharge parallel to joists.HOUSINGMOUNTINGTABSPOWER CABLE ADDITIONALFRAMING"I"JOIST"I"JOISTGRILLEPANGLASS LIGHT SHADECEILINGMATERIALHOUSINg MOUNTED TO “I” jOISTRequires additional framingfor mounting tabs.Discharge parallel to joists.* Additional framing must be a 2x6 (minimum height), at least 9-inches long.**WARNINgTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, ORINJURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit only in the manner intended by the manufacturer.If you have questions, contact the manufacturer at the addressor telephone number listed in the warranty.2. Before servicing or cleaning unit, switch power off at servicepanel and lock the service disconnecting means to preventpower from being switched on accidentally. When the servicedisconnecting means cannot be locked, securely fastena prominent warning device, such as a tag, to the servicepanel.3. Installation work and electrical wiring must be done by aqualified person(s) in accordance with all applicable codesand standards, including fire-rated construction codes andstandards.4. Sufficient air is needed for proper combustion and exhaustingof gases through the flue (chimney) of fuel burning equip-ment to prevent backdrafting. Follow the heating equipmentmanufacturer’s guideline and safety standards such as thosepublished by the National Fire Protection Association (NFPA),and the American Society for Heating, Refrigeration and AirConditioning Engineers (ASHRAE), and the local code authori-ties.5. When cutting or drilling into wall or ceiling, do not damageelectrical wiring and other hidden utilities.6. Ducted fans must always be vented to the outdoors.7. NEVER place a switch where it can be reached from a tub orshower.8. This unit must be grounded.9. This unit is U.L. listed. Type I.C. inherently protected.CAUTION !1. For general ventilating use only. Do not use to exhaust hazard-ous or explosive materials and vapors.2. This product is designed for installation in FLAT CEILINGSONLY. Do not mount this product in a wall.3. The light fixture assembly must be mounted to the fan housingassembly included with this product. Do not mount the lightfixture assembly to a wiring outlet box.4. To avoid motor bearing damage and noisy and/or unbalancedimpellers, keep drywall spray, construction dust, etc. off powerunit.5. Please read specification label on product for further informa-tion and requirements.Installer:Leave this manual with thehomeowner.Homeowner:Use and Care information on page 4.PLAN THE INSTALLATIONThe unit will operatemost quietly andefficiently whenlocated where theshortest possibleduct run andminimum numberof elbows will beneeded.Use a roof cap orwall cap that has abuilt-in damper toreduce backdrafts.Plan to supply theunit with properline voltage andappropriate powercable. 4-in. ROUnDELBOW(S) *4-in.ROUnDDUCT *WALL CAP ** PurchaseseparatelyinSULATiOn(Can be placedaround and overfan housing.)fAnhOUSingSUSPENDED CEILINgSHousing hung with wires -3-point mount.MOUNTINGTABGRILLEPANSUSPENDEDCEILINGMATERIALPOWERCABLE4" ROUNDDUCTHOUSINGGLASSLIGHT SHADE