Numens 4001 User Manual
Also see for 4001: Installation and service manual
4001 non-addressable control and indicating equipmentUser Manual9 33-0012-r11_2018-03© 2015 ~ 2018 Ambest Electronics (Ningbo) Co Ltd. All rights reserved.All specifications and other information shown were current at the date of publication and subject to change without notice.3.7. Test ConditionTests can be conducted by a single person. To enter the Test Condition and undertake tests of the 4001 andconnected devices, follow these steps:3.7.1. Indicator Test1) Enter Access Level 1 or Access Level 2.2) Press the INDICATOR TEST button. The internal sounder will operate. All LED indicators on the controland indicating equipment and any connected remote displays will illuminate until the INDICATOR TESTbutton is released.3.7.2. Device Test1) Enter Access Level 3.2) Press INDICATOR TEST button. The TEST LED and the ACK LED will flash. B 1 LED will be on.3) Press the NEXT button to select the alarm zone to test. The alarm zone will be indicated on LEDs B 1 ~ B 8.4) Press the ACK button to confirm. The TEST LED will be on steady and the FAULT TEST DISABLE LED ofthe selected Zone will flash.5) Test a device connected to each detection zone. Upon activation of the device: the FIRE LED will illuminate for 5 s; the Detector Zone indicator will illuminate for 5 s; any connected remote display Detection Zone indicator will illuminate for 5 s; and the internal sounder, and alarm devices will operate for 1 s.Zones will automatically reset after 10 s.6) At the completion of the tests and to exit the Test Condition, press the INDICATOR TEST button. The TESTLED will flash and the ACK LED will flash.7) Press the ACK button to confirm. The ACK LED will be off. The TEST LED in the STATUS section and theTEST FAULT DISABLED LEDs in the ZONES section will be off. The control and indicating equipment willremain in Access Level 3.3.8. Delays Active/InactiveTo inhibit pre-configured delays to the Alarm Condition, take the following actions:1) When the Alarm Condition is not present, enter Access Level 2.2) Press the DELAYS ACTIVE button. The DELAYS ACTIVE LED will flash, and the ACK LED will flash.3) Confirm the selection by pressing the ACK button. The ACK LED will be off and the DELAYS ACTIVE LEDwill be off. The control and indicating equipment will remain in Access Level 2. In the Alarm Condition, delays can be disabled at Access Level 1. If an alarm is waiting to be processed when the delays are disabled, the control andindicating equipment will immediately enter the Alarm Condition. For the Delays Active/Inactive function, the zones must first be configured to enablethe delay at Access Level 3. If the delay function is not set, the DELAYS ACTIVE LED will not light. |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine