-23-• Stop the alarm by pressing “start/stop”.• Insert the Flocare® Infinity™ feeding set into the pump asindicated on the blister packaging (or refer to Fig 5a - 5d)and close the door.• Restart the pump.• Clean the sensors, reinsert the feeding set in the pumpand restart the pump.• Stop the alarm and prolong the hold mode with another 3minutes by pressing “start/stop” key.• Program the pump and start it by pressing the “start/stop”.• The set is not fitted or wrongly fittedin the pump.• The pressure sensor area is dirty(Fig 1, position 5 & 6)• The pump has been untouched inhold mode for 3 minutes or more.NO SETPUSH STRTALARM FUNCTIONS AND SAFETY FEATURESIn case any of the problems listed on the problem solver chart occur, the pump delivers an audible and visualalarm and stops working. The back light of the LCD automatically switches on.Exception to this is the low battery alarm “BATT”, in this situation the pump continues working.Action in the event of an alarm:Check the type of alarm displayed by the large display characters.• Press the “start/stop” key to stop the audible and visual alarm.• Correct the cause of the alarm as described in the table.• Start the pump again by pressing “start/stop”.The problem solver chart on the next page gives a clear explanation of the alarms.MAINTENANCECleaning:• Always unplug the pump prior to cleaning to avoid electric shock hazard.• On a regular basis thoroughly clean all surfaces of the pump (including the sensors and rotor) with warmsoapy water, a 5% bleach solution in water, a multipurpose disinfectant cleaner or a soft cloth.• The Flocare® Infinity™+ pump may be rinsed by holding under a stream of warm, clean water. Do not sub-merge the pump!• Always maintain the rollers on the rotor in a clean state to ensure they spin freely.• The adaptor normally does not require cleaning. When desired, a dry or slightly damp cloth may be usedto clean the outside surface of the adaptor. Make sure the adaptor is disconnected from the wall outlet.Safety notes:• The manufacturer recommends an inspection of the pump at an authorised service centre every 2 years.• If any fault occurs during use, or if the pump is dropped, it should be checked by authorised technical per-sonnel prior to use.• Replace the Flocare® Infinity™ pump set every 24 hours to maintain delivery accuracy and prevent thegrowth of harmful bacteria. Dispose of Flocare ® Infinity ™ disposable sets properly, as required by local law.• Do not use the Infinity alarm systems to trigger actions related to secondary (electrical) medical devices(e.g. a volumetric or syringe pump).• Do not use pump functions (e.g. the fill set function) for any other purpose than described in this manual,as this may cause the pump to incorrectly calibrate.PROBLEM SOLVER CHARTCondition Cause CorrectionAlways follow the instructions below in case a problem occurs.Using methods other than those described may cause the pump to function incorrectly.UKZMNL900097_AW.indd 25 24/01/12 7:29 PM