7. Use and maintenance manual B01.13 San Maurizio C.se - 23/11/2018 www.omcr.itPic.3MAXIMUM CAPACITY LOADEC MARKCONSTRUCTORPRODUCT CODEWORK ORDERNUMBERIn case of lifting and handling, the lifting bracket capacity load must not be lower than ½ of the total die weightEx: Die weight 7.000 kgMinimum capacity load of the lifting bracket: 7.000 / 2 = 3.500 kgDon’t make lifting/handling with slings that have an angle of over 90° to the horizontal level,in opposed case can happen the extraction of the pin with the risk of load fall (see Pic.4).WARNING3.7Pic.4Before each lifting or handling check that the lifting brackets capacity load is in compliancewith the die weight; the maximum capacity load, the work order number, the constructorlabel and the EC conformity mark are indelibly marked over the lifting brackets. (see Pic.3).WARNING3.6