Oase Aquamax 2000 Operating Instructions Manual
Also see for Aquamax 5500: Operating instructionsCommissioningDirections for use
Contents |
7- GB -Safety informationPos: 39 /Alle Produkte/Sicherheit/SIC Sicherheitshinweise Einleitung @ 7\mod_1205310799730_121.doc @ 45453The company OASE has built this unit according to the state of the art and the valid safety regulations. Despite theabove, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accor-dance with its intended use, or if the safety instructions are ignored.Pos: 40 /Alle Produkte/Sicherheit/SIC Kinder und Jugendliche unter 16 Jahren @ 6\mod_1196356502951_121.doc @ 41194For safety reasons, children and young persons under 16 years of age as well as persons who cannot recognisepossible danger or who are not familiar with these operating instructions, are not permitted to use the unit.Pos: 41 /Pumpen/Schlammsauger/Aquamax Start 2000, 3500, 5500, 8500/Die Kombination von Wasser Aquamax Start 2000-8500 @ 4\mod_1156401100694_121.doc @ 24613The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected ormisused. Only operate the unit if no persons are in the water! Prior to reaching into the water, always disconnect thepower supply to all units used in the water. Compare the electrical values of the power supply with those on the typeplate on the packaging or on the unit itself. Ensure that the unit is fused for a rated residual current of max. 30 mA via aresidual current-operating system. Only operate the unit when plugged into a correctly fitted socket. Keep the powerplug and all connection points dry! Protect the connection cable when burying to avoid damage. Only use cables,equipment, adapters, extension or connection cables with an earthed contact and approved for outside use. Do notcarry or pull the unit by the connection cable! Never operate the unit if the cable or housing are defective! Aquamax3500, 5500, 8500: In case the mains connection cable of the unit is damaged, have it replaced by the manufacturer orthe customer service in order to prevent hazards. Aquamax 2000: This unit does not allow a change of the powercable! If the cable is damaged, the entire unit has to be disposed of. Electrical installations at garden ponds must meetthe international and national regulations valid for installers. Never open the unit housing or its attendant components,unless this is explicitly mentioned in the operating instructions. Never carry out technical changes to the unit. Only useoriginal spare parts and accessories. Only allow authorised customer service outlets to perform repairs. Never run theunit without water! Never use the pump for fluids other than water! For your own safety, consult a qualified electrician ifyou have questions or encounter problems!Pos: 42 /Pumpen/Schlammsauger/Aquamax ECO/Elektrischer Anschluss Aquamax ECO @ 0\mod_1126270337051_121.doc @ 3961Electrical connectionOnly entrust an authorised expert to carry out the electrical connection in accordance with the German EVU and VDE.VDE 0100 Part 702 is valid for all installations. Refer to the type plate for all capacity parameters. Only perform anywork on the unit when isolated!Pos: 43 /Pumpen/Schlammsauger/Aquamax Start 2000, 3500, 5500, 8500/Inbetriebnahme Aquamax Start 3500-8500 @ 4\mod_1154689266694_121.doc @ 22913Start-upAttention! Never operate the unit without filter basket or without water!Only use the unit in its horizontal position and ensure stable seating on a firm ground. The unit must be positionedbelow the water surface level. Connect the hose and fasten it with a hose clip (B3). The unit switches on automaticallywhen connected to power.Pos: 44 /Pumpen/Schlammsauger/Aquamax Start 2000, 3500, 5500, 8500/Reinigung Aquamax Start 3500-8500 @ 4\mod_1154690253622_121.doc @ 22939Maintenance and cleaningAttention! Always disconnect the power supply prior to starting cleaning and maintenance work!Important! Aquamax 3500, 5500, 8500: Never open the pump yourself! Contact a qualified electrician if therotor is blocked by soiling!Aquamax 3500, 5500, 8500: Should the capacity drop, clean the filter housing under running water using a soft brush.Pull the power plug prior to starting cleaning. Undo the screw at the underside of the strainer casing (B5) and removethe casing. Disengage the retaining clamps (B5) and take the pump out of the strainer casing (B6). Clean the pumpunder running water using a soft brush. Remove soiling from the impeller vanes through the openings. Never open themotor housing. Danger to life! After cleaning, fit the unit in the reverse order.Aquamax 2000: Dismantle the pump (C) if the rotor is blocked by soiling: Screw off the pump housing. Pull out therotor, clean, check and, if necessary, replace. Reassemble in the reverse order.Pos: 45 /Pumpen/Schlammsauger/Aquamax Start 2000, 3500, 5500, 8500/Verschleißteil Aquamax Start 2000-8500 @ 4\mod_1154691067662_121.doc @ 23017Wearing partsAquamax 2000: Impeller unit, foam filter and rear bearing are wear parts and are excluded from the warranty.Pos: 46 /Pumpen/Schlammsauger/Aquamax Start 2000, 3500, 5500, 8500/Lagern/Überwintern Aquamax Start 3500-8500 @ 4\mod_1154690658895_121.doc @ 22965Storage/Over-winteringRemove the unit at temperatures below zero degrees centigrade. Thoroughly clean the unit, check for damage andstore immersed in water in a frost-free environment. Do not immerse the plug! (D)Pos: 47 /Alle Produkte/Entsorgung - gem. Bestimmungen/Fachhändler @ 0\mod_1125578523312_121.doc @ 1407DisposalDispose of the unit in accordance with the national legal regulations.Pos: 48 /Pumpen/Schlammsauger/Aquamax Start 2000, 3500, 5500, 8500/Störung Aquamax Start 3500-8500 @ 4\mod_1154690788719_121.doc @ 22991SMalfunctionMalfunction Cause RemedyPump does not start No mains voltage Check mains voltageClean/check supply linesPump does not deliver Filter housing clogged Clean strainer casingsReduce hose length to the necessary minimum,do not use unnecessary connection partsInsufficient delivered quantity Filter housing cloggedExcessive loss in the supply hosesClean strainer casingsReduce hose length to the necessary minimum,do not use unnecessary connection partsPump switches off after a short running time Excessively soiled waterWater temperature too highClean pumpNote maximum water temperature of +35°CPos: 49 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1630 |
Related manuals for Oase Aquamax 5500
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine