Oase Filtoclear Series Operating Instructions Manual
Also see for Filtoclear 11000: Directions for useOperating instructions
Contents |
8Use other than that intendedDanger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case ofmisuse. If used for purposes other than that intended, our warranty and operating permit will become null and voidCE Manufacturer's DeclarationWe declare conformity in the sense of the EC directive, EMC directive (89/336/EEC) as well as the low voltage directive(73/23/EEC). The following harmonised standards apply: EN 60598-1, EN 60598-2-1, EN 55015, EN 61000-3-2,EN 61000-3-3Signature:Safety informationOASE has manufactured this unit according to the highest quality standards and the valid safety regulations. Despite theabove, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accordancewith its intended use, or if the safety instructions are ignored.For safety reasons, children and young persons under 16 years of age as well as persons who cannot recognisepossible danger or who are not familiar with these operating instructions, are not permitted to use the unit!Please keep these operating instructions in a safe place! Also hand over the operating instructions when passing the uniton to a new owner. Ensure that all work with this unit is only carried out in accordance with these instructions.The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected andmisused.Attention! Dangerous ultra-violet radiation.The radiation of the UVC lamp is dangerous for eyes and skin! Never operate the unit lamp ouside of its housing. Neverimmerse the unit in water! Always disconnect the power supply of all units located in water and of this unit prior toperforming work on the unit! Only operate the unit when plugged into an earthed socket. The latter must have beeninstalled in accordance with the valid national regulations. Ensure that the protective earth wire is led to the unit. Neveruse installations, adapters, extension or connection cables without protective earth contact! The cross section of powerconnection cables must not be smaller than the rubber cables identified with H05 RNF. Extension cables must meet DINVDE 0620. Ensure that the unit is supplied via a fault current protection (FI or RCD) with a reference fault current of 30mA maximum. Protect the connection cable when burying to avoid damage. Only use cables approved for external use.Protect the plug connection against humidity/moisture. Never operate the unit if the cable or housing are defective!Disconnect the power! Do not carry or pull the unit by the connection cable. Electrical installations at garden ponds andswimming pools must meet the international and national regulations valid for installers. Compare the electrical data ofthe supply with those on the unit type plate. This data must agree. For your own safety, consult a qualified electrician ifyou have questions or encounter problems! The power connection cable cannot be replaced. If damaged, the unit has tobe disposed of.Do not operate the unit if persons are in the water! Never use the pump for fluids other than water! Never open the unithousing or its attendant components, unless this is explicitly mentioned in the operating instructions. Never run the unitwithout water!Attention! The outlet from the filter cannot be more than 2m (0.2 bar water pressure) vertically above the level ofthe filter!Ensure that no leaks at the filter can occur. Danger of completely emptying the pond.InstallationPlace the unit at a flood protected position at a distance from the pond edge of at least 2 m on a firm and level ground.As an alternative, the filter can be burried up to the recess in the container. Maximum height difference between filter lidand outlet point: max. 2 m (14). Do not expose the unit to direct sun radiation. Ensure unrestricted access to the cover tobe able to carry out work on the unit.InstallationFitting hose connectionsThe max. pump head height is 5m WC (0.5 bar). Only operate the unit with pressure hoses which are approved at leastfor 0.2 bar or the maximum pump pressure. Saw off the stepped hose nozzle at the appropriate point of the correspondinghoses (13). Push or screw the hoses onto the stepped hose nozzle and secure with a hose clip.Installation at the water inletPush the union nut over the black stepped hose nozzle, fit the hose, insert the flat sealing ring in the union nut, and screwonto the water inlet socket.Installation at the water outletPush the union nut over the transparent stepped hose nozzle, fit the hose, insert the green flow indicator flag into theunion nut, and screw onto the water outlet socket.Installation at the cleaning connectionTo permanently fit a drain hose to the cleaning connection, unscrew the cover cap from the cleaning connection, pushthe union nut over the transparent hose nozzle, fit the hose, insert the green flow indicator flap into the union nut, andfirmly tighten it on the cleaning connection. During filter operation, ensure that the cleaning connection or a drain hoseconnected to it is always closed with the cover cap and the inserted flat sealing ring as a security measure, should thefunction switch be unintentionally set to „Cleaning". To close the drain hose with the cover cap, push or turn the blackstepped hose nozzle with its thread onto the hose and secure with the hose clip, firmly screw tighten with the flat sealingring inserted.Attention! Never operate the unit without water or without pump strainer casing!GB |
Related manuals for Oase Filtoclear 11000
Oase Filtoclear Operating Instructions Manual
Oase Filtoclear Operating Instructions Manual
Oase filtoclear 20000 Operating Instructions Manual
Oase FiltoClear 3000 Operating Instructions Manual
Oase FiltoClear 5000 Operating Instructions Manual
Oase FiltoClear 1600 Operating Instructions Manual
Oase FiltoClear 3000 Operating Instructions Manual
Oase FiltoClear 5000 Operating Instructions Manual
Oase Filtoclear 3.000 Operating Instructions Manual
Oase FiltoClear 12000 Operating Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine