Oki Data CONFIDENTIAL 3. Parts replacement44983601TH Rev.1 3-29 /3.3.22 Plate Side R Assy(1) Separate the Plate Side R Assy. (Refer to 3.3.20)(2) Remove the two screws (Silver) . Remove the Guide-Cassette-R .(3) Remove the two screws (Black) . Remove the Connector .(4) Remove the four screws (Silver) . Remove the Plate-ID-Gear , Gear-Idle-Z21 , Gear-Idle-Z30-33 .(5) Remove the screw (Silver) . Remove the Holder-Switch and Micro switch .(6) Remove the two screws (Silver) , screw (Black) . Remove the Guide-ID-R and Motor-Fan(X40), Board-974 , Spring-ID Lock R .(7) Remove the Guide-Cable .(8) Installing is performed by the inverse procedure with removing.(Note on removing / installing)1. Beware of not to touch the DC motor inattentively (Do not rotate motor).2. Install Motor-FAN with the label side inward and with its notch fitted to the appropriate projectionof Guide-ID-R .3. While removing or installing FAN , do not press impeller of the FAN as shown by the followingphoto. In case of the impeller unfastened by mistake, do not reuse it and install a new FAN .View AProjectionNotchImpeller