3. OTHER MAINTENANCE ITEM Field Service Ver. 1.0 Jul. 200926FS-529MAINTENANCE3.3.18 Belt retract solenoid (SD5)1. Remove the front left cover.See P.62. Remove the spring [1], and removethe lever [2].3. Remove the harness from the wiresaddle [1].4. Disconnect the connector [2].5. Remove the screw [3], and removethe belt retract solenoid [4].6. Reinstall the above parts following the removal steps in reverse.A0U7F2C039DA[1][2]A0U7F2C040DA[1][2][3][4]Service Manual Y111310-1