5. Mechanical adjustment Field Service Ver. 1.0 Mar. 200632FS-603Adjustment / Setting5.4 Adjustment of the Folding Position• Folding position is adjusted by adjusting the Tray Section and the Saddle Section.• Adjust the folding position by aligning the Tray Section. Adjust the position of the SaddleSection if the position is still not proper.5.4.1 Adjustment procedureA. Checking the deviation amount1. Load the Paper Take-up Tray with A3paper.2. Select “Fold & Staple” and touch“OK.”3. Place the A3 Original (Blank paperacceptable) to the original tray, andpress the Start key.4. Check the fed out copy to see if thereis any deviation.B. Adjusting the folding deviation1. Turn main power switch OFF, andremove the Finisher from themachine.2. Remove the cable, and remove theHorizontal Unit [1].Paper SizeAmount of deviation which willbe adjusted by aligning the TraySectionAmount of deviation which willbe adjusted by aligning theSaddle Section positionTotal amount whichwill be adjustedA3 0.55 mm 0.55 mm 1.1 mmA4 0.4 mm 0.4 mm 0.8 mmB4 0.5 mm 0.5 mm 1.0 mmLedger 0.55 mm 0.55 mm 1.1 mmLetter 0.35 mm 0.35 mm 0.7 mm4583F3E525DAExitdirectionExitdirectionDeviated upwardDeviated downward4583F3C518DA[1]Service Manual Y104710-1