6) Press the [START] key, and the automatic developer adjust-ment will be performed.During execution of the automatic developer adjustment,“EXECUTING...” is displayed and the toner sensor value isindicated on the LCD. (DEVE REFERENCE)7) After about 2 min, the adjustment value is stored in themachine. Check that the mode was normally completed.In case of an error end, remove the cause of the error, andexecute the automatic developer adjustment again.8) Turn off/on the power, and the machine returns to the normalmode and enters the warm-up mode.9. Print test1) After completion of warm-up (normal mode), select [CUSTOMSETTINGS] → [Data list up] to display the menu.2) Print [ALL SETUP LIST] to check and confirm the print quality.3) Press the [CUSTOM SETTINGS] key again to return to thenormal menu.10. Distortion adjustmentNote: This adjustment must be performed after installing themachine and its peripheral devices.It is basically no need to perform the adjustment because it hasbeen made when shipping. If there should be a distortion asshown in the figure below, perform the adjustment according tothe following procedures.1) Use a level gauge to check to confirm that the scanner unit isinstalled horizontally.Make a copy, and if any distortion is found as shown in Fig 1or Fig. 2, loosen the scanner fixing screw (M4 x 8) and thecam A fixing screw (M3 x 12) to make an adjustment.• Case of Fig. 1Shift the cam A in the direction of A by the difference of the image.For one scale (one groove), shift by 0.5mm.After shifting the cam, tighten the cam A fixing screw (M3 x 12).Make a copy again and check to confirm that there is no distortionon the image.• Case of Fig. 2Shift the cam A in the direction of B by the difference of the image.For one scale (one groove), shift by 0.5mm.After shifting the cam, tighten the cam A fixing screw (M3 x 12).Make a copy again and check to confirm that there is no distortionon the image.After adjustment, tighten the fixing screw (M3 x 12) and the scan-ner fixing screw (M4 x 8).Attach the decoration seal to the screw hole.(DSPF scan position automatic adjustment)1) Execute SIM 53-8 after completion of the distortion adjust-ment.2) If any distortion is made after execution of the simulation, exe-cute the MB rail position adjustment. (Refer to "3-A OC scandistortion adjustment (MB-B rail height adjustment)" in [8]ADJUSTMENTS.)11. Attach the document scanning label12. Adjuster installation and adjustment1) Insert the left adjuster into the paper feed desk.2) Turn each adjuster until it is brought into contact with the floor.∗ Be sure to install the left adjuster in order to prevent falling downof the machine.Note: If the adjusters are not lowered to the specified positions,the lower stage tray cannot be pulled out.Normal end: Returns to the initial window (PRESSSTART display).Abnormal end: Returns to the initial window (PRESSSTART display), and indicates the troubledisplay (TROUBLE! EE-**).Fixing screw(M4x8)First copy image[Fig. 1]DifferenceImagePaperFirst copy image[Fig. 2]DifferenceImagePaperReferenceReference6mm15mm1 2222Y105220-6 Sevice Manual 6-13