15Cable resistance per wire (max.), RTD............ 50 ΩSensor current, RTD........................................... Nom. 0.2 mAEffect of sensor cable resistance(3-/4-wire), RTD................................................ < 0.002 Ω / ΩSensor error detection, RTD ............................ YesShort circuit detection, RTD ............................ < 15 ΩInputtypeMin.valueMax.value StandardPt10...Pt1000Ni50...Ni1000Cu10...Cu100Lin. RPotentiometer-200°C-60°C-200°C0 Ω10 Ω+850°C+250°C+260°C10000 Ω100 kΩIEC 60751DIN 43760α = 0,00427--Specifications 8TypeMin.valueMax.value StandardBEJKLNRSTUW3W5LR0°C-100°C-100°C-180°C-200°C-180°C-50°C-50°C-200°C-200°C0°C0°C-200°C+1820°C+1000°C+1200°C+1372°C+900°C+1300°C+1760°C+1760°C+400°C+600°C+2300°C+2300°C+800°CIEC 60584-1IEC 60584-1IEC 60584-1IEC 60584-1DIN 43710IEC 60584-1IEC 60584-1IEC 60584-1IEC 60584-1DIN 43710ASTM E988-90ASTM E988-90GOST 3044-84Section 8.3 - TC input