Page 38Kore 7th Manual / kHLab Edition5.2. ConnectionConnect Allows establishing the connection with doser on the chooseCOM port nr (this port is assigned to doser during the installationprocess).Disconnect Close connection/communication with doser.Refresh all settings By pressing this button you can refresh/load all important dosersettings. It can take up to two-three minutes.BlueTooth Connection group boxActive Alarms group boxTemperature alarm If that alarm is active it mean that your water temperature is aboveor below maximum/minimum settings (check this on ATO/Tempconfig).Liquids alarm(low level)If active – liquid level (in any container) reached minimum level(configured in ATO/Temp config).ATO alarm(no refill)Active when ATO tried refill four times without success. Checkthat your DC pump is working or refill container isn’t empty.High water level Your sump water level is too high(above top floating level switch).It can be also activated by optical sensor working as a safetysensor (you can set working mode for the optical sensor in thelast Service TAB).pH1 alarm Active when pH is Lower than pH#1 set in “pH ports / kHLabconfig” TAB.pH2 alarm Active when pH is Lower than pH#2 set in “pH ports / kHLabconfig” TAB.This group box shows all active doser alarms: