E-19Basic operation (Continued)3) M.PED volumeWhen the volume operation is enabled, theunit operates in the absolute value modewhere the value is fixed in accordance withthe position of the volume. The value will be“0” by clicking the center.The variable amount is within a rangebetween the minimum value of –200 and themaximum value of +200 with the center valueof 0.Operation of the scene fileThe unit has five sets of scene files and iscapable to storing the current settings as a scenefile or loading the stored settings.It is also possible to store/call scene files usingthe SD memory card. For details, refer to“Saving/Loading of scene files onto the SDmemory card” (page 21).1) Operation of the scene fileWhen the lamp of the RECORDER ENABLEbutton is off, the scene files are operatedusing the seven buttons on the top right sideof the unit.Storing: Select a file number to store usingbuttons 1 to 5 (blue letters). Whenthe button is pressed, the buttonlamp will flash. If the SAVE (blueletters) button is pressed in thisstate, the SAVE button lamp willalso flash. To store the file, pressthe SAVE button again. When thestore operation is finished, thelamp of the button for the stored filenumber turns on.When the lamps for buttons 1 to 5are flashing, press the button orleave for 10 seconds or more torelease the selection.Loading: Select a file number to load usingbuttons 1 to 5 (blue letters). Whenthe button is pressed, the buttonlamp will flash. If the LOAD buttonis pressed in this state, theselected file will load. At this time,the lamp of the VR ACTIVE buttonflashes, the operation mode of thevolume set in the unit menu isignored, and the unit is in therelative value mode.