< Function setting switch 1This is used to select the operations of the AW-EX500.Before changing a setting, the power must be turned off.The setting items are shown below.1: Input signal setting 1 (Factory setting: ANALOG)Set this to match the input signals which will be used.2: Input signal setting 2 (Factory setting: VIDEO)3: Input signal setting 3 (Factory setting: YC)Input signal settings 2 and 3 take effect when has been selected as input signal setting 1.Set as shown below to match the analog signals whichare to be input to analog video input connectors 5, 6and 7.4: Input signal level setting Y <714mV/700mV>(Factory setting: 700mV)When analog component signals have been selectedas the input signals, select this setting by determiningwhether the white 100% signal level of the inputsignals is 714mV or 700mV.When VIDEO signals or YC signals are to be input, setto 700mV.5: Input signal level setting R-YB-Y <756mV/525mV>(Factory setting: 525mV)When analog component signals have been selectedas the input signals, select this setting by determiningwhether the color signal level of the input signals is756mV or 525mV.When VIDEO signals or YC signals are to input, set to525mV.- 9 -1234567890ONINPUT SEL2 INPUT SEL3 Input signalVIDEO Y/C VIDEOVIDEO YR-YB-Y VIDEOYR-YB-Y, Y/C Y/C Y/CYR-YB-Y, Y/C YR-YB-Y YR-YB-YON OFF SW NOPB302 PB310 ADDITIONAL I/F SEL 0PB302 PB310 OPTION I/F SEL 9YR-YB-Y RGB PB302 OUT SEL (ADD) 8YR-YB-Y RGB PB302 OUT SEL (OPT) 7ADDITIONAL IF OPTION IF RS232C SEL 6756mV 525mV INPUT LEVEL R-YB-Y 5714mV 700mV INPUT LEVEL Y 4YR-YB-Y YC INPUT SEL3 3YR-YB-Y, YC VIDEO INPUT SEL2 2SDI ANALOG INPUT SEL1 1 PreviousNext |