The genlock adjustment is performed to achieve phase alignment byapplying external synchronization (genlock) when a multiple number ofcameras will be used or when the unit will be used in combination withother devices.This unit supports BBS (Black Burst Sync) and tri-level sync externalsynchronization signals.Ask your dealer to perform this adjustment.(Use a dual-trace oscilloscope for the adjustment.)Horizontal phase adjustmentObserve the waveforms of the external sync signal input (tri-level syncsignal) and video signal output on the dual-trace oscilloscope, and usethe wireless remote control or controller to bring the horizontal phaseinto alignment.External sync signalinput(tri-level sync signal)Video signal outputBring the horizontalphase into alignment.Example: When the tri-level sync phase is adjustedWhen performing operations from a wirelessremote control1. Follow the operation steps in “Basic operations” (→page 37) to display the Top Menu.2. Press the <4> or <5> button to bring the cursor to[System].Top MenuCamera Scene: Scene1SystemMaintenance3. Press the <M> button.The [System] screen appears.SystemGenlockOutputOthersReturn4. Press the <4> or <5> button to bring the cursor to[Genlock], and press the <M> button.The [Genlock] sub-menu is displayed.GenlockHorizontal Phase 0Horizontal Phase Step 1Return5. Press the <4> or <5> button to bring the cursor to[Horizontal Phase], and press the <M> button.The [Horizontal Phase] value starts blinking.6. Press the <4> or <5> button to change the [HorizontalPhase] value, adjust the value so that the horizontalphase is brought into alignment, and press the <M>button.The extent of the phase adjustment can be selected using [HorizontalPhase Step].7. Press and hold the The camera menu display is exited.When performing operations from a controllerThese operations can be performed using the camera menus byfollowing the operation steps in “Basic operations” “Basic operations”(→pages 37 to 46).Genlock adjustment36