16O IO IO IConnections∫When using the RS-232C interface and control panel tocontrol the pan/tilt headAW-PH500Pan/tilt headfor ENGapplicationsAW-PS505AC adapterAW-PS505AC adapterAW-RP301Pan-tilt control panelAW-PS505AC adapterLens zoom/focus cableENG cameraColor monitorZoom lensVideo camera control cableAW-CA16U10 (10 meters)AW-CA16U20 (20 meters)AW-CA16U30 (30 meters)Pan/tilt head control cableAW-CA24U10 (10 meters)Component signalsRS-232CconnectorG/L signals(5C-2V coaxial cable)PC10 BaseT straight cable(UTP category 5)Max. distance of 500 meters (when extended) betweenpan/tilt head and controller (monitor, G/L source)≥ Keep the length of the cable between the pan/tilt head and PC to less than 15 meters.To extend the cable to a length exceeding 15 meters, convert the interface from RS-232C to RS-422 for sending, andconvert it back to RS-232C at the receiving end.≥ Use a crossover cable between the pan/tilt head and PC.≥ Refer to the connections with the PC in the section entitled “When using the RS-232C interface to control the pan/tilt head”for directions on how to connect the pan/tilt head control cable and RS-232C cable.≥ If a hybrid panel is used as the control panel when the AW-F575 is to be used as the ENG camera, the camera can becontrolled from the control panel. In this case, the connections between the control panel and pan/tilt head and betweenthe camera and pan/tilt head are the same as described in the section entitled “When the AW-F575 is used as the camerato be installed” under “When using the control panel.”≥ The camera cannot be controlled using the RS-232C interface.∫ Exercising control using contactsTo exercise control using contacts, connect the contact control inputs of the pan-tilt control contractor to DGND. (Pull-up to5 V inside the pan/tilt head)Refer to the connector specifications.