Page 1-25REGULARMAINTENANCE1Check Every 140 Hours (Once a Week)1-4-2 Cleaning and Lubricating the Tape Feeder TableClean and lubricate the tape feeder table.∗ For DU/DHU specifications, it is necessary to remove the feeder base cover for the maintenance.“1-2-3 Setting and Removing the Feeder Base Cover (Only for DU/DHU Specifications)”1. Turn OFF the servo switch.2. Open the safety cover.3. Clean the surroundings of the tapefeeder tables with the vacuum cleaneror cleaning brush.∗ If chip components have dropped on the tapefeeder tables, the tape feeder ski will bedamaged and the pick-up position may bedislocated. And, what’s worse, pick-up errorscan be increased. Before changing productionmodels or the tape feeder parts, be sure toclean there.4. Ensure that there is no damage to thetip of the projection rod.5. Apply grease to the linear-bearing railgrooves for the double tape feeder.∗ Only when the optional double tape feeder isinstalled, carry out this operation.To the next page444C-E-MMA01-A04-04Tools Required time 5 minutesClothOFF ( ) ON ( )SERVO444C-509P444C-409PProjection rodLinear bearingTape feeder table444C-509PRail groove