Airflow Direction Auto-Control• When set a Airflow Direction Auto-Control with remotecontrol, the louver swings up and down as shown in thediagram.• The louver does not swing when the Indoor Fan stopsduring operation.• When stopped with remote control, the discharge vent isclosed with the louver.The left and right airflow direction louvers can be adjustedmanually.1 There is no swinging while indoor fan is stopped duringCooling and Soft Dry operation.2 In Heating operation, when the indoor heat exchangertemperature rises to 38°C, the airflow direction is changedfrom upper limit to lower limit. When the indoor heatexchanger temperature falls to 35°C, the air flow directionis changed from lower limit to upper limit.Airflow Direction Manual Control• When the airflow direction set button is pressed, theautomatic airflow is released and the airflow direction louvermove up and down in the range shown in the diagram.The louver can be stopped by releasing the button at thedesired louver position.• When the remote control is used to stop the operation, thedischarge vent is closed with airflow direction louver.The left and right airflow direction louvers can be adjustedmanually.8.8. Airflow Direction Control8.9. Delay ON Timer Control• When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so thatthe room will reach nearly to the set temperature by the desired time.• For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.• For Heating mode, the operation will start 30 minutes before the set time.• For Automatic mode, the indoor fan will operate at SLo speed for 20 seconds, 30 minutes before the set time to detect theintake air temperature to determine the operation mode. The operation indication lamp will blink at this time.8.10. Cold Draught Control• When COMP = Thermal OFF, indoor fan speed immediately changed to SLo for 30 sec., followed by SSLo speed until COMP= ON.During cold draft c/m operation, fan speed will be SSLo only.SSLo: Fan will be running at Lo speed with SSR ON for 0.6 sec. and OFF for 5.0 sec.21CS-A28BKP5/CU-A28BKP5