7SETTING THE TIMEREnsure that the current time is correct before setting thetimer. The timer cannot be set if the time display isflashing. ON-TIMER OperationTo start the air conditioner operation automatically.• Press 1 to set the operation.• Press 2 to increase or decrease the time.• Then press 3.• To cancel this operation, press 4. OFF-TIMER OperationTo stop the air conditioner operation automatically.• Press 5 to set the operation.• Press 2 to increase or decrease the time.• Then press 3.• To cancel this operation, press 4. Timer Mode Operation Details• When the ON-Timer is set, operation will startbefore the actual set time. This is to enable theroom temperature reaches the set temperature atthe set time.• Once the ON-Timer is set, operation will start at theset time everyday.• The current time is not displayed when the timersare set.• When both timers are used together, the TIMERmode indicator on the indoor unit remains lit evenwhen the operation is stopped by the OFF-TIMER.CONVENIENCE OPERATION Sleep Mode OperationTo obtain a comfortable room temperature whilesleeping:-• Press 6.• Sleep mode indicator on the indoor unit will light up.• To cancel this operation, press once more. Sleep Mode Operation Details• When the room temperature reaches the settemperature, the airflow volume will change to lowautomatically.• Sleep Mode Operation time is 8 hours.• When used together with the timer, the timer has apriority. Economy Mode OperationTo save electrical power consumption.Please use this mode when the room has reachedyour desired temperature.• Press 7.* Economy mode indicator (green) on the indoor unitwill light up.• Press once more to cancel this operation. Powerful Mode OperationTo obtain the set temperature quickly.• Press 8.* Powerful mode indicator (orange) on the indoorunit will light up.* Powerful mode will operate for 15 minutes only.• To cancel this operation, press once more. Economy / Powerful Mode Operation Details• Economy and Powerful operation cannot beselected simultaneously.• The changes of the temperature and airflow volumeare automatic.• The remote control display remains unchanged.• If sleep button or operation mode button is pressed,economy or powerful operation will be cancelled.• During FAN – Air circulation operation, the powerfuland economy operation are not available.CHECKAUTOAUTO HEAT DRY FANCOOLFANAUTORESET CLOCKMODE SLEEPECONOMYFAN SPEEDAIR SWINGOFF CANCELON SET1 2 3TIMEROFF/ONPOWERFULAUTO MANUAL36417528COOL, DRY, 15 minutesAUTO in advanceAirflowvolumeSuper LowSuper HighEconomy ModeOperationPowerful ModeOperationTemperature1°F higherthan set temp.5°F lowerthan set temp.TimeApprox. 1°Fincrease.TemperatureSleepOperationbutton ispressed.Sleep shiftoperationstarts.0~1 hourafter approx. 8 hours of sleep shiftoperation, it will stop automatically.Approx.1°Fincrease. • Cooling or Soft DryOperation for sleep shiftoperation will start toavoid overcooling.SettingTemperature ← 1 hour →