3412.7.2. Manual Control• When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflowdirection vane move left and right in the range shown in the diagram.The louver can be adjusted by pressing the button to the desired vane position.• When stopped with remote control, the vanes is reset, and stopped at reset position.12.8. Powerful Operation• To achieve the setting temperature quickly.• When Powerful operation is set, the setting temperature will be automatically decreased 3qC internally against the presentsetting temperature (Lower temperature limit: 16qC).• This operation automatically will be running under SHi Fan Speed (Cooling).• Vertical Airflow Direction:-- In “Manual” setting, the vane will automatically shift down 10q lower than previous setting.- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10q downward.• Powerful operation stops when:-- Powerful operation has operate for 4 hours.- Powerful button is pressed again.- Quiet button is pressed.- Stopped by OFF/ON operation button.- Timer OFF activates.- Operation mode is changed.