10.2.1. SELECT THE BEST LOCATION(Refer to “Select the best location”section)10.2.2. HOW TO FIX INSTALLATIONPLATEThe mounting wall is strong and solid enough to prevent it fromthe vibration.: Unit centre should be at more than 450 mm at right and leftof the wall.The height should be more than 195 mm from the ceiling.: From installation plate end to unit left side end is 50 mm.: From installation plate end to unit right side end is 50 mm.: Connecting cable should be about 750 mm from this line.(Only for left rear piping): For left side piping, piping connection for liquid should behere.: For left side piping, piping connection for gas should behere.1. Mount the installation plate on the wall with four screws.(If mounting the unit on the concrete wall consider usinganchor bolts.)• Always mount the installation plate horizontally byaligning the marking-off line with the thread and using alevel gauge.2. Drill the piping plate hole with ø70 mm hole-core drill.• Line according to the arrows marked on the lower leftand right side of the installation plate. The meeting pointof the extended line is the centre of the hole.• Drill the piping hole at either the right or the left and thehole should be slightly slanted to the outdoor side.10.2.3. TO DRILL A HOLE IN THE WALLAND INSTALL A SLEEVE OFPIPING1. Insert the piping sleeve to the hole.2. Fix the bushing to the sleeve.3. Cut the sleeve until itextrudes about 15 mm from the wall.CautionWhen the wall is hollow, please be sure to use thesleeve for tube ass’y to prevent dangers caused bymice biting the indoor/outdoor connecting cable.4. Finish by sealing the sleeve with putty or caulkingcompound at the final stage.10.2.4. INDOOR UNIT INSTALLATION1. For the right rear piping2. For the right and right bottom piping10.2. INDOOR UNIT52S-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE