3412.6. Vertical Airflow Direction Control12.6.1. Auto Control• When the vertical airflow direction is set to Auto using the remote control, the louver swings up and down as shown in thediagram.• When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.• During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that condition, thelouver will stop swinging and rest at the upper limit.12.6.2. Manual Control• When the vertical airflow direction is set to Manual using the remote control, the automatic airflow is released and the airflowdirection louver move up and down in the range shown in the diagram.• The louver can be adjusted by pressing the button to the desired louver position.• When stop operation using the remote control, the discharge vent is reset, and stop at the closing position.12.7. Horizontal Airflow Direction Control• The horizontal airflow direction louvers can be adjusted manually by hand.12.8. Powerful Operation• To achieve the setting temperature quickly.• When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against the presentsetting temperature (Lower temperature limit: 16°C).• This operation automatically will be running under SHi fan Speed (Cooling), Lo- Fan Speed (Soft Dry).• Vertical Airflow Direction:-- In “Manual” setting, the vane will automatically shift down 10° lower than previous setting.- In “Auto” setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.• Powerful operation stops when:-- Quiet/Powerful button is pressed again.- Powerful operation has operate for 15 minutes.- Stopped by OFF/ON operation button.- Timer OFF activates.- Operation mode is changed.