8.1.2. Frequency Instruction for Compressor OperationOperation of compressor is based on instructed frequency, continuously from indoor unit´s microcomputer after performingtemperature sampling and judgment.There are total 30 different frequency values, which listed as Table on Frequency Number, to be instructed based on thetemperature judgmentTable on Frequency NumberNo. Frequency (Hz) RemarksE9CKP E12CKP/E15CKP1 12.0 12.0 Freq. MIN2 15.0 15.03 18.0 18.04 21.0 21.05 23.0 23.06 25.0 25.07 26.0 28.08 30.0 32.09 33.0 36.010 35.0 40.011 36.0 44.012 38.0 48.013 39.0 52.0 Fc14 40.0 57.015 47.0 62.0 Fc max. (E9CKP)16 49.0 67.0 Fc max. (E12CKP/E15CKP)17 56.0 68.5 Fh18 58.0 72.019 63.0 76.020 66.0 80.021 70.0 85.022 73.0 88.023 77.0 91.024 80.0 94.025 83.0 98.026 86.0 102.027 87.0 104.028 88.0 106.029 89.0 108.030 90.0 110.0 Fh max.For normal start of operation, including Thermo-OFF, Deice-Resuming, and remote controller ON-OFF starts, the compressorstarts to operate at frequency no. 8, values of 30Hz and 32Hz for E9CKP and E12CKP/E15CKP respectively, for 60 seconds.The frequency to be judged and instructed, however, starts to judge once the air conditioner operated and the judgment willcontinue every 30 seconds until it is stopped by all kinds of compressor off conditions. This judgment is based on the internaltemperature sampling that involving internal setting temperature and intake air temperature.From the internal sampling, the temperature different (intake air temperature - internal setting temperature) will be used to judgethe Zone on which the frequency to be instructed for the initial operation of compressor (refer to Table on Initial Frequency Zone).Table on Initial Frequency ZoneTemperature, X (°C) Zone Freq. No. - E9CKP Freq. No. - E12CKP/E15CKP(Intake Air - Internal Setting) Cooling Soft Dry Heating Cooling Soft Dry HeatingX -2.5 0 1 4 30 1 4 30-2.5 X -1.5 1 1 4 30 1 4 30-1.5 X -1.0 2 1 4 10 1 4 10-1.0 X -0.5 3 1 4 7 1 4 7-0.5 X +1.0 4 4 4 4 4 4 4+0.5 X +1.0 5 6 6 1 6 6 1+1.0 X +1.5 6 9 7 1 9 8 1+1.5 X +2.5 7 15 7 1 16 8 1X +2.5 8 15 7 1 16 8 1After the initial operation, the instructed frequency will change or shift from initial frequency according to the judgment ontemperature different from sampling (refer to the Table on Shifting Frequency Zone).15CS-E15CKP CU-E15CKP5