3712.1.5. Automatic Operation• This mode can be set using remote control and the operation is decided by remote control setting temperature, remote controloperation mode, indoor intake air temperature and outdoor air temperature.• During operation mode judgment, indoor fan motor (with speed of Lo-) and outdoor fan motor are running for 30 seconds todetect the indoor intake and outdoor air temperature. The operation mode is decided based on below chart.Every 30 minutes, the indoor and outdoor temperature is judged. Based on remote control setting temperature, the value of T1 willincrease up to 10qC, T2 will decreased by 3qC and T3 will decreased up to 8qC.The Auto Operation Mode shifting will take place whenever operation mode changed from Cooling/Soft Dry to Heating or viceversa.12.1.6. Indoor Fan Motor OperationA. Basic Rotation Speed (rpm)i. Manual Fan Speed[Cooling, Dry]• Fan motor’s number of rotation is determined according to remote control setting.[Heating]• Fan motor’s number of rotation is determined according to remote control setting.ii. Auto Fan Speed [Cooling, Dry]• According to room temperature and setting temperature, indoor fan speed is determined automatically.• The indoor fan will operate according to pattern below.Remote Control O O O O OTab (rpm) Hi Me+ Me Me- LoRemote Control O O O O OTab (rpm) Shi Me+ Me Me- Lo