3112.1.5 Automatic Operation This mode can be set using remote control and the operation is decided by remote control setting temperature,remote control operation mode and indoor intake air temperature. During operation mode judgment, indoor fan motor (with speed of Lo-) is running for 30 seconds to detect theindoor intake air temperature. Every 10 minutes, the indoor temperature is judged. For the 1st judgmento If indoor intake temperature - remote control setting temperature ≥ 3.6°F, COOL mode is decided.o If -3.6°F ≤ indoor intake temperature - remote control setting temperature < 3.6°F, DRY mode is decided.o If indoor intake temperature - remote control setting temperature < -3.6°F, HEAT mode is decided. For the 2nd judgment onwardso If indoor intake temperature - remote control setting temperature ≥ 5.4°F, if previous operate in DRY mode,then continue in DRY mode. Otherwise COOL mode is decided.o If -3.6°F ≤ indoor intake temperature - remote control setting temperature < 5.4°F, maintain with previousmode.o If indoor intake temperature - remote control setting temperature < -3.6°F, HEAT mode is decided.12.2 Indoor Fan Motor Operation12.2.1 Basic Rotation Speed (rpm) Manual Fan Speed[Cooling, Dry]o Fan motor’s number of rotation is determined according to remote control setting.Remote control ○ ○ ○ ○ ○Tab Hi Me+ Me Me- Lo[Heating]o Fan motor’s number of rotation is determined according to remote control setting.Remote control ○ ○ ○ ○ ○Tab Shi Me+ Me Me- Lo Auto Fan Speed[Cooling, Dry]o According to room temperature and setting temperature, indoor fan speed is determined automatically.o The indoor fan will operate according to pattern below.o During operation, indoor fan motor may stop due to odor prevention.