71. Cooling capacities are based on indoor temperature of 27C Dry Bulb (80.6F Dry Bulb), 19.0C Wet Bulb (66.2F Wet Bulb)and outdoor air temperature of 35C Dry Bulb (95F Dry Bulb), 24C Wet Bulb (75.2F Wet Bulb)2. Heating capacities are based on indoor temperature of 20C Dry Bulb (68F Dry Bulb) and outdoor air temperature of 7C DryBulb (44.6F Dry Bulb), 6C Wet Bulb (42.8F Wet Bulb)3. Heating low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20C, outdoor 2/1C.4. Heating extreme low temperature capacity, Input Power and COP measured at 230 V, indoor temperature of 20C, outdoor-7/-8C.5. Specifications are subjected to change without prior notice for further improvement.Thermostat Electronic Control Electronic ControlProtection Device Electronic Control Electronic ControlDry Bulb Wet Bulb Dry Bulb Wet BulbIndoor Operation RangeCooling Maximum 32 23 32 23Minimum 16 11 16 11Heating Maximum 30 — 30 —Minimum 16 — 16 —Outdoor Operation RangeCooling Maximum 43 26 43 26Minimum 16 11 16 11Heating Maximum 24 18 24 18Minimum -5 -6 -5 -6MODEL INDOOR CS-E24MKES CS-E28MKESOUTDOOR CU-E24MKE CU-E28MKE