8.2.22. Indication PanelLed POWER MONITOR POWER SLEEP TIMER POWERFULColor Orange Green Orange Orange OrangeLight ON Operation ON Operation ON Sleep Mode ON Timer Setting ON Powerful Mode ONLight OFF Operation OFF Operation OFF Sleep Mode OFF Timer Setting OFF Powerful Mode OFFNote:• If POWER LED is blinking, the possible operations of the unit are Hot Start, during Deice operation, operation modejudgment, or delay ON timer sampling.• If Timer LED is blinking, there is an abnormality operation occurs.8.2.23. Auto Operation Switch1. When the switch is pressed between 0 to 5 seconds, Auto Mode operation starts to function.2. When the switch is pressed between 5 to 8 seconds, the unit is forced to operate in Cooling Mode.3. When the switch is pressed between 8 to 11 seconds, the unit is forced to operate in Heating Mode.4. When the switch is pressed between 11 to 16 seconds and together with the signal from remote control, the unit can bechanged to different controlling setting (A-B mode).5. When the switch is pressed between 16 to 21 seconds, either “H14” error detection selection mode or the remote controller´ssignal receiving sound can be cancelled or turned on.35CS-E9BKP CU-E9BKP5 / CS-E12BKP CU-E12BKP5Panasonic ilmalämpöpumput korjaa ja huoltaa pääkaupunkiseudulla: Jäähdytinpalvelu RefGroup Oywww.ilmalämpöpumput.com