32 Product Specification2.1. CS-F18DTE5 CU-B34DBE51. Cooling capacities are based on indoor temperature of 27°C D.B. (80.6°F D.B.), 19.0°C W.B. (66.2°F W.B.) and outdoor airtemperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)2. Heating capacities are based on indoor temperature of 20°C D.B. (68°F D.B.) and outdoor air temperature of 7°C D.B. (44.6°FD.B.), 6°C W.B. (42.8°F W.B.)ELECTRICAL DATA (50 Hz)ITEM / MODEL Indoor Unit Outdoor UnitMain Body CS-F18DTE5 × 2 CU-B34DBE5RemoteControlCZ-RD513C (Wired)CZ-RL513T (Wireless)Cooling Capacity kW 10.0BTU/h 34,100Heating Capacity kW 11.2BTU/h 38,200Refrigerant Charge-less m 30Standard Air Volume for High, m 3 /min 14 94cfm 494 3316Outside Dimension (H x W x D) mm 210 × 1245 × 700 1170 × 900 × 320inch 8-9/32 × 49-1/64 × 27-9/16 40-1/16 × 35-7/16 × 12-19/32Net Weight kg (lbs) 33 (73) 102 (225)PipingConnectionRefrigerant Gas mm (inch) O.D Ø 12.70 (1/2) Flared TypeLiquid mm (inch) O.D Ø 6.35 (1/4) Flared TypeDrain O.D Ø 20 I.D Ø 20Compressor Type, Number of Set - Hermetic, 1Starting Method - Permanent Split CapacitorMotor Type - 2-pole 1 phase brushless motorRated Output kW - 3.0Fan Type, Number of Set Sirocco fan-4 Mix flow fan,1Motor Type 4-pole single phase induction motor 6-pole single phase induction motorRated Output kW 0.022 0.07 × 2Air-heat Exchanger (Row x Stage x FPI) Louver-fin type (2 × 12 × 18) Corrugate-fin type (2 × 44 × 20)Refrigerant Control - Expansion ValveRefrigerant Oil (Charged) cm 3 - DAPHNE FVC68D (1500)Refrigerant (Charged) R410a kg (oz) - 2.70 (96)RunningAdjustmentControl Switch Wireless or Wired Remote Control -Room Temperature Thermostat -Noise Level dB (A) Cooling: 41/37 55/-Heating: 41/37 56/-Power LeveldBCooling: 58/54 69/-Heating: 58/54 70/-Moisture Removal L/h (Pt/h) 6.0 (12.6)EER W/W 2.52/2.49/2.46COP W/W 2.84/2.81/2.77ITEM / MODEL Condition by ISO5151Volts V 220 230 240Phase Single Single SinglePower Consumption kW Cooling 3.85 3.90 3.95Heating 3.94 3.99 4.04Running Current A Cooling 17.8 18.2 18.7Heating 18.0 18.2 18.4Starting Current A 92 95 98Power Factor % Cooling 99 94 91Heating 99 95 91*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.Panasonic Power source AC, 1~220V,230V, 240V 50Hz