5213.12 +8/10°C Heat Operation +8/10°C Heat operation provides heating at low setting temperature in unoccupied houses during winter for thepurpose of protecting equipments or housing appliances which may be destroyed by the extreme cold weather. This operation can be ON by pressing the +8/10°C heat button on the remote control. Two temperature settings are available, which are;o 8°C (Pressing TEMP down button at the remote control)o 10°C (Pressing TEMP up button at the remote control) During the operation of this mode;o The indoor fan speed will remain at Hi fan tap all the time included deice process.o Powerful operation, Quiet operation, Econavi operation and Fan Speed selection are disabled.o Cold draft prevention control is disabled. Control condition;TEMP TEMPTEMP TEMPMODE +8/10°CHEATMODE +8/10°CHEATMODE +8/10°CHEATMODE +8/10°CHEATOFF/ONOFF/ONOFF/ONOFF/ONOFF/ON+8/10°CHEATMODE(Go back to previousMODE LCD setting &transmit code)(Transmit+8/10°C HEATN-type code)MODE(Go back to previousMODE LCD setting &transmit code)MODE(Go back topreviousMODE LCDsetting &transmitcode)MODE(Go back topreviousMODE LCDsetting &transmitcode)#1+8/10°CHEAT(Transmit+8/10°C HEATN-type code)+8/10°CHEAT(Transmit+8/10°C HEATN-type code)+8/10°CHEAT(Transmit+8/10°C HEATN-type code)#1+8/10°CHEAT(Transmit+8/10°C HEATN-type code)+8/10°CHEAT (Transmit+8/10°C HEATN-type code)Reach ON timer (OR)(2) Set temperature range is 8°C / 10°C.NOTE:(1) “#1” : “+8/10°C HEAT” mode or “RFP” mode set temperature follows previously fixed set temperature(+8°C or +10°C). But after battery reset, (default condition) set temperature always start with +8°C. Caution!If the indoor temperature constantly is less than 0°C (Door, windows not close properly), the error code F11 mayoccur. This is because in open area, the indoor sensor will misjudge operation condition and will give error code.