5510.10 Indication PanelLED POWER TIMER nanoe ECONAVIColor White White White WhiteLight ON Operation ON Timer Setting ON nanoe ON ECONAVI ONLight OFF Operation OFF Timer Setting OFF nanoe OFF ECONAVI OFFNote: If POWER LED is blinking, the possible operation of the unit are Hot Start, during Deice operation, operationmode judgment, or ON timer sampling. If Timer LED is blinking, there is an abnormality operation occurs.10.11 nanoe Operation This operation provides clean air by producing great amount of negative ions and distribute through thedischarge airflow to capture or deactivate molds, bacteria or viruses. Generate nanoe (water wrapped ion particle) to moisturize skin. nanoe operation start conditiono During unit running at any operation mode, if nanoe operation is activated, combination operation (operationmode + nanoe operation) starts.o During unit is OFF, if nanoe operation is activated, nanoe individual operation starts. nanoe operation stop conditiono When OFF/ON button is pressed to stop the operation.o When nanoe button is pressed.o When OFF Timer activates. nanoe operation pause conditiono When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe operation resume afterindoor fan restarts.o When indoor intake temperature ≥ 35°C and < 5°C. nanoe operation resume after indoor intake temperature< 35°C or ≥ 5°C continuously for 6 minutes. Indoor fan controlo During any operation mode combines with nanoe operation, fan speed follows respective operation mode.However, nanoe system enabled when fan speed ≥ 470 rpm to ensure proper negative ion distribution,nanoe system disabled when fan speed < 470 rpm.o During nanoe individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if FanSpeed button is pressed, no signal is sent to the unit and no change on remote control display. Auto FanSpeed for nanoe individual operation is cooling medium fan. Airflow direction controlo During any operation mode combines with nanoe operation, airflow direction follows respective operationmode.o During nanoe individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, nosignal is sent to the unit and no change on remote control display. Timer controlo When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoeoperation status.o When ON Timer activates during any operation, no change on current operation.o When OFF Timer activates during any operation, all operation stops and the latest nanoe operation status issaved. Indicatoro When nanoe starts, nanoe indicator ON.