36C. Control contentsa. Fan Speed manual1. Fan speed is changed from normal setting to quiet setting of respective fan speed.This is to reduce sound of Hi, Me, Lo for 3dB.2. Fan speed for quiet operation is reduced from setting fan speed.b. Fan Speed Auto1. Indoor FM RPM depends on pipe temp sensor of indoor heat exchanger.12.7. Powerful Mode Operation• When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft Dry) or higher upto 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve the setting temperature quickly.12.8. Timer Control12.8.1. ON Timer Control• ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time. This is to providea comfortable environment when reaching the set ON time.• 60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to determine theindoor intake air temperature and outdoor air temperature in order to judge the operation starting time.• From the above judgment, the decided operation will start operate earlier than the set time as shown below.12.8.2. OFF Timer ControlOFF timer can be set using remote control, the unit with timer set will stop operate at set time.12.9. Auto Restart Control1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to fourminutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly) afterpower supply resumes.2. This type of control is not applicable during ON/OFF Timer setting.12.10. Indication PanelNote:• If POWER LED is blinking, the possible operation of the unit are Hot Start, operation mode judgment, or ON timer sampling.• If Timer LED is blinking, there is an abnormality operation occurs.• If e-ion LED is blinking, there is an abnormality of e-ion occurs.• If PATROL LED is blinking, there is a gas sensor error detection.LED POWER/DIECE TIMER QUIET POWERFUL e-ion +8/10°C HEAT PATROLSENSORColor Green Blue Orange Orange Orange Blue Green BlueLight ON Operation ON Deice Operation Timer Setting ON Quiet Mode ON Powerful ModeON e-ion ON +8/10°C HEATON PATROL ONLight OFF Operation OFF Timer Setting OFF Quiet Mode OFF Powerful ModeOFF e-ion OFF +8/10°C HEATOFFPATROLOFF