3511.3 Outdoor Unit11.3.1 Install the Outdoor Unit After selecting the best location, start installation according to Indoor/Outdoor Unit Installation Diagram.1 Fix the unit on concrete or rigid frame firmly and horizontally by bolt nut (ø10 mm).2 When installing at roof, please consider strong wind and earthquake.Please fasten the installation stand firmly with bolt or nails.A BCDModel A B C DRE9***,UE9***,YE9***UE12***,YE12*** 570 mm 105 mm 18.5 mm 320 mmRE12***RE15***UE18***540 mm 160 mm 18.5 mm 330 mmRE18***RE24*** 613 mm 131 mm 16 mm 360.5 mm11.3.2 Connect the Piping11.3.2.1 Connecting the Piping toIndoorPlease make flare after inserting flare nut (locate atjoint portion, of tube assembly) onto the copper pipe.(In case of using long piping)Connect the piping Align the center of piping and sufficiently tightenthe flare nut with fingers. Further tighten the flare nut with torque wrench inspecified torque as stated in the table.Do not overtighten, overtightening may cause gas leakage.Piping size Torque6.35 mm (1/4”) [18 N•m (1.8 kgf.m)]9.52 mm (3/8”) [42 N•m (4.3 kgf.m)]12.7 mm (1/2”) [55 N•m (5.6 kgf.m)]15.88 mm (5/8”) [65 N•m (6.6 kgf.m)]19.05 mm (3/4”) [100 N•m (10.2 kgf.m)]11.3.2.2 Connecting the Piping toOutdoorDecide piping length and then cut by using pipe cutter.Remove burrs from cut edge.Make flare after inserting the flare nut (located at valve)onto the copper pipe.Align center of piping to valves and then tighten withtorque wrench to the specified torque as stated in thetable.TorquewrenchSpanneror Wrench