8312.13 Mild Dry Cooling Operation• This operation helps to prevent decreases in room humidity while maintaining the setting temperature.• During unit running at Cooling operation mode, if “Mild Dry Cooling” button is pressed, Mild Dry Cooling operationstarts and Mild Dry Cooling indicators turns ON at remote control display.• Mild dry cooling operation is unavailable when the unit is operating Auto mode, Soft Dry mode, Patrol individualoperation or e-ion individual operation.• Mild dry cooling operation is cancelled when the unit turned OFF, pressed again Mild Dry Cooling button or whenthe operation mode changed from Cooling to other mode.• ECONAVI, Powerful, Quiet and Mild Dry Cooling mode cannot function at the same time, the unit will follows theoperation according to the last signal received.• During this operation, the compressor frequency changes according to operating condition to prevent roomhumidity decreases and when AUTO AIR SWING is set, the vertical airflow direction fixed at lower limit position.12.14 AUTO COMFORT and ECONAVI Operation• Area of human availability, activity level and absent is judged based on pulses by using 2 infrared sensors. Theinternal setting temperature shift, fan speed and horizontal airflow direction are adjusted in order to providecomfort environment while maintain the energy saving level.• AUTO COMFORT start condition: When AUTO COMFORT button is pressed.• AUTO COMFORT stop conditions: When AUTO COMFORT button is pressed again. When unit is OFF by OFF/ON button. When unit is OFF when OFF TIMER activates. When unit is OFF by AUTO OFF/ON button at indoor unit. When POWERFUL, QUIET or MILD DRY operation activates. When ◄► button is pressed.• ECONAVI start condition: When ECONAVI button is pressed.• ECONAVI stop conditions: When ECONAVI button is pressed again. When unit is OFF by OFF/ON button. When unit is OFF when OFF TIMER activates. When unit is OFF by AUTO OFF/ON button at indoor unit. When POWERFUL, QUIET or MILD DRY operation activates. When ◄► button is pressed.• AUTO COMFORT / ECONAVI initializationInitialize indication Human Activity Indicator1 0 – 2 seconds □ □ □2 2 – 3 seconds ■ ■ ■I ■ □ ■II ■ ■ □III ■ □ ■IV □ ■ ■3 3 – 70 secondsRepeat Step I to IV* □ Indicator ON, ■ Indicator OFF