Panasonic CS-TZ20ZKE Series Installation Instruction
65 mmor more(Left and right are identical)Installation plateSleeve ( )Bushing-Sleeve ( )Bend the pipe asclosely on the wall aspossible, but be carefulthat it doesn’t break.Saddle ( )Putty ( )(Gum Type Sealer)Installation parts youshould purchase ( )50 mmor moreVinyl tape (wide) ( )• Apply after carryingout a drainage test.• To carry out thedrainage test,remove the air fi ltersand pour water intothe heat exchanger.Power supply cord ( )It is advisable to avoid morethan 2 blockage directions.For better ventilation &multiple-outdoor installation,please consult authorizeddealer/specialist.Indoor/Outdoor Unit Installation Diagram50 mmor more(*)ENGLISHACXF60-47630PRINTED IN MALAYSIASAFETY PRECAUTIONS• Read the following “SAFETY PRECAUTIONS” carefully before installation.• This installation manual must be used together with another installation manual incorporated in applicable outdoor unit as complete full set of instructions.• Confi rm the type of gas used before installation.• Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed.• The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation dueto ignoring of the instruction will cause harm or damage, and the seriousness is classified by the following indications.WARNING This indication shows the possibility of causing death or serious injury.CAUTION This indication shows the possibility of causing injury or damage to properties only.The items to be followed are classified by the symbols:Symbol with white background denotes item that is PROHIBITED.Symbol with dark background denotes item that must be carried out.• Carry out test running to confirm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in instructions. Pleaseremind the customer to keep the operating instructions for future reference.WARNINGDo not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. Any unfit method or using incompatible material may cause productdamage, burst and serious injury.Do not install outdoor unit near handrail of veranda. When installing air-conditioner unit on veranda of a high rise building, child may climb up to outdoor unit and cross over the handrailcausing an accident.Do not use unspecified cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor contact, poor insulation orover current will cause electrical shock or fire.Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.Do not insert your fingers or other objects into the unit, high speed rotating fan may cause injury.Do not sit or step on the unit, you may fall down accidentally.Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing.When installing or relocating air conditioner, do not let any substance other than the specified refrigerant, eg. air etc mix into refrigeration cycle (piping). Mixing of air etc. will cause abnormalhigh pressure in refrigeration cycle and result in explosion, injury etc.Do not pierce or burn as the appliance is pressurized. Do not expose the appliance to heat, flame, sparks, or other sources of ignition.Else, it may explode and cause injury or death.Do not add or replace refrigerant other than specified type. It may cause product damage, burst and injury etc.• For R32/R410A model, use piping, flare nut and tools which is specifi ed for R32/R410A refrigerant. Using of existing (R22) piping, fl are nut and tools may cause abnormally highpressure in the refrigerant cycle (piping), and possibly result in explosion and injury.For R32 and R410A, the same flare nut on the outdoor unit side and pipe can be used.• Since the working pressure for R32/R410A is higher than that of refrigerant R22 model, replacing conventional piping and flare nuts on the outdoor unit side are recommended.• If reuse piping is unavoidable, refer to instruction “IN CASE OF REUSING EXISTING REFRIGERANT PIPING”• Thickness of copper pipes used with R32/R410A must be more than 0.8 mm. Never use copper pipes thinner than 0.8 mm.• It is desirable that the amount of residual oil less than 40 mg/10 m.Engage authorized dealer or specialist for installation. If installation done by the user is incorrect, it will cause water leakage, electrical shock or fire.For refrigeration system work, install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fire.Use the attached accessories parts and specified parts for installation. Otherwise, it will cause the set to fall, water leakage, fi re or electrical shock.Install at a strong and firm location which is able to withstand weight of the set. If the strength is not enough or installation is not properly done, the set will drop and cause injury.For electrical work, follow the national regulation, legislation and this installation instructions. An independent circuit and single outlet must be used. If electrical circuit capacity is not enoughor defect found in the electrical work, it will cause electrical shock or fire.Do not use joint cable for indoor / outdoor connection cable. Use the specified indoor/outdoor connection cable, refer to instruction CONNECT THE CABLE TO THE INDOOR UNIT and connecttightly for indoor/outdoor connection. Clamp the cable so that no external force will have impact on the terminal. If connection or fixing is not perfect, it will cause heat up or fire at the connection.Wire routing must be properly arranged so that control board cover is fixed properly. If control board cover is not fi xed perfectly, it will cause fi re or electrical shock.This equipment is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD), with sensitivity of 30 mA at 0.1 sec or less.Otherwise, it may cause electrical shock and fire in case of equipment breakdown or insulation breakdown.During installation, install the refrigerant piping properly before running the compressor. Operation of compressor without fixing refrigeration piping and valves at opened position will causesuck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.During pump down operation, stop the compressor before removing the refrigeration piping. Removal of refrigeration piping while compressor is operating and valves are opened will causesuck-in of air, abnormal high pressure in refrigeration cycle and result in explosion, injury etc.Tighten the flare nut with torque wrench according to specified method. If the flare nut is over-tightened, after a long period, the flare may break and cause refrigerant gas leakage.After completion of installation, confirm there is no leakage of refrigerant gas. It may generate toxic gas when the refrigerant contacts with fi re.Ventilate if there is refrigerant gas leakage during operation. It may cause toxic gas when the refrigerant contacts with fire.Be aware that refrigerants may not contain an odour.This equipment must be properly earthed. Earth line must not be connected to gas pipe, water pipe, earth of lightning rod and telephone.Otherwise, it may cause electrical shock in case of equipment breakdown or insulation breakdown.CAUTIONDo not install the unit in a place where leakage of flammable gas may occur. In case gas leaks and accumulates at surrounding of the unit, it may cause fi re.Prevent liquid or vapor from entering sumps or sewers since vapor is heavier than air and may form suffocating atmospheres.Do not release refrigerant during piping work for installation, re-installation and during repairing refrigeration parts. Take care of the liquid refrigerant, it may cause frostbite.Do not install this appliance in a laundry room or other location where water may drip from the ceiling, etc.Do not touch the sharp aluminium fin, sharp parts may cause injury.Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water may enter the room and damage the furniture.Select an installation location which is easy for maintenance.Incorrect installation, service or repair of this air conditioner may increase the risk of rupture and this may result in loss damage or injury and/or property.Power supply connection to the room air conditioner.Use power supply cord 3 x 1.5 mm² (3/4 ~ 1.75HP), 3 x 2.5 mm² (2.0HP) type designation 60245 IEC 57 or heavier cord.Connect the power supply cord of the air conditioner to the mains using one of the following method.Power supply point should be in easily accessible place for power disconnection in case of emergency.In some countries, permanent connection of this air conditioner to the power supply is prohibited.1) Power supply connection to the receptacle using power plug.Use an approved 15/16 A (3/4 ~ 1.75HP), 16 A (2.0HP) power plug with earth pin for the connection to the socket.2) Power supply connection to a circuit breaker for the permanent connection.Use an approved 16 A (3/4 ~ 2.0HP) circuit breaker for the permanent connection. It must be a double pole switch with a minimum 3.0 mm contact gap.Installation work.It may need two people to carry out the installation work.Keep any required ventilation openings clear of obstruction.PRECAUTION FOR USING R32 REFRIGERANT• Pay careful attention to the following precaution points and the installation work procedures.When connecting flare at indoor side, make sure that the fl are connection is used only once, if torqued up and released, the fl are must be remade. Once the flare connection wastorqued up correctly and leak test was made, thoroughly clean and dry the surface to remove oil, dirt and grease by following instructions of silicone sealant. Apply neutral cure(Alkoxy type) & ammonia-free silicone sealant that is non-corrosive to copper & brass to the external of the flared connection to prevent the ingress of moisture on both the gas &liquid sides. (Moisture may cause freezing and premature failure of the connection)The appliance shall be stored, installed and operated in a well ventilated room with indoor floor area larger than Amin (m²) [refer Table A] and without any continuously operatingignition source. Keep away from open flames, any operating gas appliances or any operating electric heater. Else, it may explode and cause injury or death.Refer to “PRECAUTION FOR USING R32 REFRIGERANT” in outdoor unit installation manual for other precautions that need to pay attention to.MODEL NO. :-CS-TZ20, TZ25, TZ35, TZ42, TZ50ZKE SeriesCS-RZ25, RZ35, RZ50ZKE SeriesApplicable piping kit Piping sizeGas LiquidCZ-3F5, 7BP 9.52 mm (3/8") 6.35 mm (1/4")CZ-4F5, 7, 10BP 12.7 mm (1/2") 6.35 mm (1/4")CZ-52F5, 7, 10BP 15.88 mm (5/8") 6.35 mm (1/4")• Pipe Size Reducer (CZ-MA1PA) for Outdoor Multi Connection CS-TZ42***,CS-TZ50***, CS-RZ50***• Please refer to “CONNECT THE PIPING” sectionSELECT THE BEST LOCATIONINDOOR UNIT Do not install the unit in excessive oil fume area such as kitchen, workshop andetc. There should not be any heat source or steam near the unit. There should not be any obstacles blocking the air circulation. A place where air circulation in the room is good. A place where drainage can be easily done. A place where noise prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall, ceiling, fence or otherobstacles. Indoor unit of this air conditioner shall be installed in a height of at least 1.8 m.Table AModel Capacity W(HP) Max. RefrigerantCharge ( ) Indoor Amin (m²)TZ20*** 3/4HP 0.60 Not applicable (*)TZ25***, RZ25*** 1.0HP 0.69 Not applicable (*)TZ35***, RZ35*** 1.5HP 0.75 Not applicable (*)TZ42*** 1.75HP 0.87 Not applicable (*)TZ50***, RZ50*** 2.0HP 1.22 Not applicable (*)(*) Systems with total refrigerant charge, mc , lower than1.84 are not subjected to any room area requirements.* Table “A” only applicable for single split connection.* In case of connection to outdoor multi inverter,refer to installation manual at outdoor unit.• This illustration is forexplanation purposes only.The indoor unit will actuallyface a different way.(*) If holder at the rear of chassis needto be used to prop up the unit, thisdistance shall be 65 mm or more.• Carry out insulation afterchecking for gas leaks andsecure with vinyl tape. Vinyl tapeRemote control holderRemote control holder fixing screwsRemote controlInsulation of piping connectionsAttaching the remote control holder to the wallINDOOR UNITCONNECT THE CABLE TO THE INDOOR UNIT2The power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.1 Install the indoor unit on the installing holder that mounted onthe wall.2 Open the front panel and grille door by loosening the screw.3 Cable connection to the power supply through Isolating Devices(Disconnecting means).• Connect the approved polychloroprene sheathed powersupply cord 3 x 1.5 mm² (3/4 ~ 1.75HP) or 3 x 2.5 mm²(2.0HP), type designation 60245 IEC 57 or heavier cord tothe terminal board, and connect the other end of the cable toIsolating Devices (Disconnecting means).• Do not use joint power supply cord. Replace the wire if theexisting wire (from concealed wiring, or otherwise) is too short.• In unavoidable case, joining of power supply cord betweenisolating devices and terminal board of air conditioner shallbe done socket and plug rated 15/16 A (3/4 ~ 1.75HP) or16 A (2.0HP). Wiring work to both socket and plug must followto national wiring standard.4 Bind all the power supply cord leadwire with tape and route the powersupply cord via the left side escapement.5 Connection cable between indoorunit and outdoor unit shall be approvedpolychloroprene sheathed 4 x 1.5 mm²(3/4 ~ 1.75HP) or 4 x 2.5 mm² (2.0HP)fl exible cord, type designation 60245 IEC57 or heavier cord.6 Bind all the indoor and outdoorConnection cable with tape and routethe connection cable via the right sideescapement.7 Remove the tapes and connect thepower supply cord and connection cablebetween indoor unit and outdoor unitaccording to the diagram below.Recommendedlength (mm)a b c d e f g30 30 60 45 40 35 55WARNINGThis equipmentmust be properlyearthed.Recommendedlength (mm)refer table belowTerminals on the outdoor unit S1 2 3 1 2 3Colour of wires (connection cable)Terminals on the indoor unit L 1 N S1 2 3 OR L 1 N S1 2 3(Power supply cord) * Connection for multiinverter model (Outdoorpower supply)Terminals on the isolating devices(Disconnecting means)(L) (N)TapePowersupplycordConnection cableTapeINSTALL THE INDOOR UNIT1For indoor unit installation, please scan the matrix two-dimensional (2D) barcode and refer to the detailed manuals.Note:• Isolating Devices (Disconnecting means) should haveminimum 3.0 mm contact gap.• Ensure the colour of wires of outdoor unit and the terminalNos. are the same to the indoor’s respectively.• Earth wire shall be Yellow/Green (Y/G) in colour andlonger than other AC wires as shown in the figure for theelectrical safety in case of the slipping out of the cordfrom the anchorage.8 Secure fi rmly the power supply cord and connecting cable ontothe control board with the holder.Do not overtighten holder screw, as this may damage the holder.9 Close grille door by tighten with screw and close the front panel.a b c4d e f g6S11S11Isolating Devices Outdoor UnitTerminal BoardPanelPanelFlip the panel downuntil ‘click’ sound beforeconnect indoor and outdoorconnection cableHolderHolderFlip thepanel downEarthWirelongerthanothersAC wiresfor safetyreasonRight escapementLeft escapementPower supplycord Indoor & outdoorconnection cableEarth Wirelonger thanothers ACwires forsafety reasonDo not joint wires.OR ORORUse complete wire without joining.Use approved socket and plug with earth pin.Wire connection in this area must follow to national wiring rules.WIRE STRIPPING, CONNECTING REQUIREMENT5 mm or moreIndoor/outdoorconnectionterminal board(gap between wires)No loosestrand wheninserted10 ± 1 mmWire strippingACCEPTConductorfully insertedPROHIBITEDConductorover insertedPROHIBITEDConductor notfully insertedCAUTIONDo not connect power supply to indoorand outdoor unit at the same time.Risk of fi re if wrong connection of powersupply.WARNINGRISK OF FIREJOINING OF WIRESMAY CAUSEOVERHEATING ANDFIRE.1. Please cut using pipe cutter and then remove the burrs.2. Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the pipingend down to avoid the metal powder entering the pipe.3. Please make flare after inserting the flare nut onto the copper pipes.When properly flared, the internal surface of thefl are will evenly shine and be of even thickness.Since the flare part comes into contact with theconnections, carefully check the flare fi nish. Improper fl aring Inclined SurfacedamagedCracked Uneventhickness1. To cut 2. To remove burrs 3. To fl areBarRed arrow markHandleCoreYokeClamp handleBar 0 – 0.5 mmCopper pipeReamerPoint downPipeDo not overtighten, overtightening may cause gas leakage.Piping size Torque6.35 mm (1/4") [18 N•m (1.8 f•m)]9.52 mm (3/8") [42 N•m (4.3 f•m)]12.7 mm (1/2") [55 N•m (5.6 f•m)]15.88 mm (5/8") [65 N•m (6.6 f•m)]19.05 mm (3/4") [100 N•m (10.2 f•m)]Connecting The Piping to Outdoor MultiDecide piping length and then cut by using pipe cutter. Remove burrs from cut edge.Make flare after inserting the flare nut (locate at valve) onto the copper pipe. Align centerof piping to valve and then tighten with torque wrench to the specified torque as statedin the table.* For Gas side piping please refer table and diagram belowOutdoor Multi Combination Model Pipe size (referto diagram)R32 ModelCS-TZ20***,CS-TZ25***,CS-TZ35***,CS-RZ25***,CS-RZ35***,CU-2Z35***,CU-2Z41***,CU-2Z50***,CU-3Z52***,CU-3Z68***,CU-4Z68***,CU-4Z80***,CU-5Z90***,CU-2TZ41***,CU-2TZ50***,CU-3TZ52***CS-TZ42***,CS-TZ50***,CS-RZ50***,CU-2Z50***,CU-3Z52***,CU-3Z68***,CU-4Z68***,CU-4Z80***,CU-5Z90***,CU-2TZ50***,CU-3TZ52***(CZ-MA1PA)Connecting The Piping to OutdoorDecide piping length and then cut by using pipe cutter.Remove burrs from cut edge.Make fl are after inserting the fl are nut (locate at valve) onto the copper pipe.Align center of piping to valve and then tighten with torque wrench to thespecifi ed torque as stated in the table.Connecting The Piping to IndoorFor connection joint of all modelsPlease make flare after inserting flare nut (locate atjoint portion of tube assembly) onto the copper pipe.(In case of using long piping)Connect the piping• Align the center of piping and sufficiently tightenthe fl are nut with fi ngers.• Further tighten the flare nut with torque wrench inspecifi ed torque as stated in the table.Torque wrenchSpanner orWrenchAdditional Precautions For R32 Models when connecting by fl aring at indoor sideEnsure to do the re-flaring of pipes before connecting to units to avoid leaking.Seal suffi ciently the fl are nut (both gas and liquid sides) with neutral cure (Alkoxy type) & ammonia-freesilicone sealant and insulation material to avoid the gas leak caused by freezing.Neutral cure (Alkoxy type) & ammonia-free silicone sealant is only to be applied after pressure testingand cleaning up by following instructions of sealant, only to the outside of the connection. The aim is toprevent moisture from entering the connection joint and possible occurrence of freezing. Curing sealantwill take some time. Make sure sealant will not peel off when wrapping the insulation.Apply neutral cure(Alkoxy type) and ammonia-freesilicone sealant along thecircumferenceHall UnionConnection pipe(female side)Auxiliary pipe(male side)Flare NutHall UnionConnection pipe(female side)Auxiliary pipe(male side)Pipe size reducer (CZ-MA1PA)Flare NutGas sideConnection pipe(female side)Auxiliary pipe(male side)Flare NutHall UnionLiquid sideCutting and Flaring The PipingCONNECT THE PIPING3Air conditionerInstallation Instruction(Simplifi ed Version)ACXF60-47630 Required tools for Installation Works1 Phillips screw driver2 Level gauge3 Electric drill, hole core drill (ø70 mm)4 Hexagonal wrench (4 mm)5 Spanner6 Pipe cutter7 Reamer8 Knife9 Gas leak detector10 Measuring tape11 Thermometer12 Megameter13 Multimeter14 Torque wrench18 N•m (1.8 kgf•m)42 N•m (4.3 kgf•m)55 N•m (5.6 kgf•m)65 N•m (6.6 kgf•m)100 N•m (10.2 kgf•m)15 Vacuum pump16 Gauge manifold• Please scan the above matrix two-dimensional (2D) barcode and read thoroughly for the detailed instruction.Panasonic will not be responsible for any accident or damage due to improper installation in anyway not described in the detailed manuals. Malfunction caused by incorrectinstallation is also not covered by product warranty.Amin = (mc / (2.5 x (LFL)(5/4) x h0)) 2Amin = Required minimum room area, in m²mc = Refrigerant charge in appliance, inLFL = Lower fl ammability limit (0.307 /m³)h0 = Installation height of the appliance (1.8 m for wall mounted)SF = Safety factor with a value of 0.75** The required minimum room area, Amin, shall also be governed bythe safety factor margin formula below :** not less than safetyfactor margin Amin =mc / (SF x LFL x h0)The higher value shall be taken when determiningthe room area.https://eu.datanavi.ac.smartcloud.panasonic.com/documents/index.htm?model=TZ20ZKEQR code forWeb Manual |
Related manuals for Panasonic CS-RZ25ZKE Series
Panasonic CS-XZ20ZKE Series Installation Instruction
Panasonic TZ71ZKE Series Installation Instruction
Panasonic CU-Z20VKE Series Installation Instruction
Panasonic K2 Series Installation Instruction
Panasonic CU-FZ25WKE Series Installation Instruction
Panasonic PE2 Series Installation Instructions Manual
Panasonic G1 Series Installation Instructions Manual
Panasonic LE1 Series Installation Instructions Manual
Panasonic Z25 Series Installation Instructions Manual
Panasonic CZ-KPU3 Series Installation Instructions Manual
manualsdatabase
Your AI-powered manual search engine