• When set a Airflow Direction Auto-Control with remotecontrol, the louver swings up and down as shown in thediagram.• The louver does not swing when the Indoor Fan Motorstops during operation at the upper limit.• When stopped with remote control, the discharge vent isreset, and stopped at the closing position.1. There is no swinging while indoor fan motor is stoppedduring Cooling and Soft Dry operation.2. In Air Circulation operation, when the intake air temperaturereaches set temperature, the airflow direction is changedfrom upper limit to lower limit. When the intake airtemperature falls to 2°C lower than set temperature, theairflow direction is changed from lower limit to upper limit.7.8. Airflow Direction Control7.9. Delay ON Timer Control• When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so thatthe room will reach nearly to the set temperature by the desired time.• For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.• For Automatic mode, the indoor fan will operate at SLo speed for 20 seconds, 15 minutes before the set time to detect theintake air temperature to determine the operation mode. The operation indication lamp will blink at this time.7.10. Remote Control Signal Receiving Sound• Long beep sound will be heard when:-− Stopping the Air Conditioner using ON/OFF switch.• Short beep sound will be heard for others.• To switch off the beep sound:-Press the “Automatic Operation Button” continuously for 10 seconds or more (“beep” “beep” will be heard at the 10th second).Repeat the above if you want to switch ON the beep sound.However, if the “Automatic Operation Button” has been pressed the Automatic operation will be activated.If you do not require this operation, you may change it by using the remote control.23CS-V12CTP CU-V12CTP5 / CS-V18CTP CU-V18CTP5 / CS-V24CTP CU-V24CTP5