DISPOSAL OF OUTDOOR UNIT DRAIN WATER• If a drain elbow is used, the unit should be placed on astand which is taller than 3 cm.• If the unit is used in an area where temperature falls below0°C for 2 or 3 days in succession, it is recommended not touse a drain elbow, for the drain water freezes and the fanwill not rotate.CHECK THE DRAINAGE• Open front panel and remove air filters.(Drainage checking can be carried out without removing thefront grille.)• Pour a glass of water into the drain tray-styrofoam.• Ensure that water flows out from drain hose of the indoorunit.EVALUATION OF THE PERFORMANCE• Operate the unit at cooling operation mode for fifteenminutes or more.• Measure the temperature of the intake and discharge air.• Ensure the difference between the intake temperature andthe discharge is more than 8°C.NOTE:These equipment shall be connected to a suitable mains networkwith a main impedance less than the following:CHECK ITEMSIs there any gas leakage at flare nut connections?Has the heat insulation been carried out at flare nutconnection?Is the connecting cable being fixed to terminal board firmly?Is the connecting cable being clamped firmly?Is the drainage OK?(Refer to “Check the drainage” section)Is the earth wire connection properly done?Is the indoor unit properly hooked to the installation plate?Is the power supply voltage complied with rated value?Is there any abnormal sound?Is the cooling operation normal?Is the thermostat operation normal?Is the remote control’s LCD operation normal?Is the super alleru-buster filter is installed??10.3.6. PIPE INSULATION1. Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit Installation Diagram. Please wrapthe insulated piping end to prevent water from going inside the piping.2. If drain hose or connecting piping is in the room (where dew may form), please increase the insulation by using POLY-E FOAMwith thickness 6 mm or above.44CS-V7DKE CU-V7DKE / CS-V9DKE CU-V9DKE / CS-V12DKE CU-V12DKE