Operation DetailsCOOL – Cooling Operation• To set the room temperature at your preferencecooling comfort.AUTO – Automatic Operation• Sense indoor temperature to select the optimummode.• Temperature is not displayed on the remote controlduring AUTO operation.DRY – Soft Dry Operation• A very gentle Cooling Operation, prior todehumidification. It does not lower the roomtemperature.• During Soft Dry operation, the indoor fan operates atLow fan speed.HEAT – Heating Operation(for Heat Pump Model only)• Heat is obtained from outdoor air to warm up theroom. When the outdoor ambient air temperaturefalls, the heating capacity of the unit might bereduced.• Defrosting OperationDepend on the outdoor temperature, the operationoccasionally stops to melt the frost on the outdoorunit.FAN – Air Circulation Operation(for Cooling Model only)• When the room temperature reaches the settemperature, operation commences at Low airflowvolume. It stops when the room temperature drops to2°C below the set temperature.(It is useful when using a heater). Setting the Fan Speed• Press 4 to select:-FAN – Low Fan SpeedFAN – Medium Fan SpeedFAN – High Fan SpeedAUTOFAN – Automatic Fan SpeedThe speed of the indoor fan is adjustedautomatically according to the operation.The indoor fan stops occasionally duringcooling operation. Setting the Vertical Airflow Direction.• Press 5 to select:- Use this air conditioner under the followingconditions: Notes• If the unit is not going to be used for an extendedperiod of time, turn off the main power supply. If it isleft at the ON position, approximately 2.5 W ofelectricity will be used even if the indoor unit has beenturned off with the remote control.• If operation is stopped, then restart immediately, theunit will resume operation only after 3 minutes.Heat Pump ModelDBT: Dry Bulb TempWBT: Wet Bulb TempMaximum TemperatureMinimum TemperatureWBT2311DBT4316WBT2611Indoor Outdoor(Unit in °C)DBT3216DBT: Dry Bulb TempWBT: Wet Bulb TempMaximum Temperature-Cooling(Maximum Temperature-Heating)Minimum Temperature-Cooling(Minimum Temperature-Heating)DBT32(30)16(16)WBT23(-)11(-)DBT43(24)16(-5)WBT26(18)11(-6)Indoor Outdoor(Unit in °C)Cooling ModelAUTO• For COOL/DRY operation.Swing up/down automatically.• For HEAT operation(For Heat Pump Model only)When the discharge air temperature islow such as at the start of the heatingoperation, the air blows at horizontallevel. As the temperature rises, the hotair blows in a downwards direction.AUTOAUTO Setting the Horizontal Airflow Direction.• Press 6 to select:-AUTOHorizontalAirflowDirectionIndoorUnitRemoteControl• For COOL/DRY operation.Swing left/right automatically.• For HEAT operation(For Heat Pump Model only)There is no air swing during the dischargeair temperature is low. When thetemperature rises, the horizontal airflowlouvers swing left/right automatically.AUTOAUTOSETTING THE TIMEREnsure that the current time is correct before setting thetimer. The timer cannot be set if the time display isflashing. ON-TIMER OperationTo start the air conditioner operation automatically.• Press 1 to set the operation.• Press 2 to increase or decrease the time.• Then press 3.• To cancel this operation, press 4. OFF-TIMER OperationTo stop the air conditioner operation automatically.• Press 5 to set the operation.• Press 2 to increase or decrease the time.• Then press 3.• To cancel this operation, press 4. Timer Mode Operation Details• When the ON-Timer is set, operation will startbefore the actual set time. This is to enable theroom temperature reaches the set temperature atthe set time.• Once the ON-Timer is set, operation will start at theset time everyday.• The current time is not displayed when the timersare set.• When both timers are used together, the TIMERmode indicator on the indoor unit remains lit evenwhen the operation is stopped by the OFF-TIMER.CONVENIENCE OPERATION Sleep Mode OperationTo obtain a comfortable room temperature whilesleeping:-• Press 6.• Sleep mode indicator on the indoor unit will light up.• To cancel this operation, press once more. Sleep Mode Operation Details• When the room temperature reaches the settemperature, the airflow volume will change to lowautomatically.• Sleep Mode Operation time is 8 hours.• When used together with the timer, the timer has apriority.Cooling Model Economy Mode OperationTo save electrical power consumption.Please use this mode when the room has reachedyour desired temperature.• Press 7.* Economy mode indicator (green) on the indoor unitwill light up.• Press once more to cancel this operation. Powerful Mode OperationTo obtain the set temperature quickly.• Press 8.* Powerful mode indicator (orange) on the indoorunit will light up.* Powerful mode will operate for 15 minutes only.• To cancel this operation, press once more. Economy / Powerful Mode Operation Details• Economy and Powerful operation cannot beselected simultaneously.• The changes of the temperature and airflow volumeare automatic.• The remote control display remains unchanged.• If sleep button or operation mode button is pressed,economy or powerful operation will be cancelled.• During FAN – Air circulation operation, the powerfuland economy operation are not available.(cooling model only)TimeApprox. 0.5°Cincrease.TemperatureSleepOperationbutton ispressed.Sleep shiftoperationstarts.0~1 hourafter approx. 8 hours of sleep shiftoperation, it will stop automatically.Approx.0.5°Cincrease. • Cooling or Soft DryOperation for sleep shiftoperation will start toavoid overcooling.SettingTemperatureCHECKAUTOAUTO HEAT DRY FANCOOLFANAUTORESET CLOCKMODE SLEEPECONOMYFAN SPEEDAIR SWINGOFF CANCELON SET1 2 3TIMEROFF/ONPOWERFUL36417528← 1 hour →Heat Pump ModelSleep shiftoperation starts.Approx. 3°Cdecrease.• Cooling or Soft DryOperation for sleep shiftoperation will start toavoid overcooling.• Heating operation forsleep shift operation willstart to avoid overheating.SleepOperationbutton ispressed.0~1 hourApprox. 2°Cdecrease.Approx.0.5°Cincrease.Approx. 0.5°Cincrease.TemperatureSettingTemperatureTime← 1 hour →after approx. 8 hours of sleep shiftoperation, it will stop automatically.AirflowvolumeSuper LowAutomaticEconomy ModeOperationCOOL / DRYHEAT(for Heat Pumpmodel only)Temperature0.5°C higherthan set temp.0.5°C lowerthan set temp.AirflowvolumeSuper HighAutomaticPowerful ModeOperationCOOL / DRYHEAT(for Heat Pumpmodel only)Temperature3°C lowerthan set temp.3°C higherthan set temp.Heat Pump ModelCOOL,DRY, – 15 minutesin advanceHEAT, AUTO – 30 minutesin advanceCooling ModelCOOL,DRY, – 15 minutesAUTO in advance← 1 hour →32CS-W18CKP CU-W18CKP5 / CS-W24CKP CU-W24CKP5