178 Operation Details8.1 .Cooling Mode OperationWhen selecting the Cooling Mode Operation, the unit will operate according to the setting by the Remote Controller orthe control panel on the indoor unit and the operation is as the following.Time Delay Safety Control3 min.----If the compressor stops, it will not restart within 3 minutes.(Protection of compressor).7 Minutes Time Save Control7 min.----The unit will automatically operate in 7 minutes even if the room temperature is not reached.(Prevention of raising the humidity)EvaporatorTemperature( ) 102Restart4 minutesCompressor ceasesTimeAnti-Freezing ControlIf temperature of evaporator is lower than 2 continuouslyfor 4 minutes, the compressor will cease to prevent theevaporator from freezing. Fan speed setting will not bechanged.When temperature of evaporator reaches 10 ,compressorwill restart.During Cooling Mode Operation, the Time Delay SafetyControl is available.Indoor FanSTOPSlow SlowSTOP STOPSlow SlowSTOPONCompressor ON1 Fan speed will be at Hi till the compressor ceases (set temperature reached).2 Fan speed will be at Me when the compressor restarts.40 30 40 3020 1601 2Automatic Fan Speed ModeDuring Cooling Mode Operation, use remote controller to select Automatic Fan Speed.Deodorization control.Fan speed will be at the point between "High speed" and "Medium speed".CS-PC12DKD / CU-PC12DKD / CS-PA12DKD / CU-PA12DKD