MANUALFive stages of adjustmentcan be made between14° ~ 36°.MANUALFive stages of adjustmentcan be made between0° ~ 61°.Heat Pump ModelMANUALFive stages of adjustmentcan be made between14° ~ 36°.Swing up/downAutomaticallyMove up/downAutomaticallyMANUALFive stages of adjustmentcan be made between0° ~ 61°.– When the discharge airtemperature is low suchas at the start of heatingoperation, the air blowsat horizontal level. Asthe temperature rises,the hot air blows at adownward direction.– To stop this operation,press MANUAL.HEAT OperationAUTOCOOL / DRY OperationAUTOSwing up/downAutomatically Operation DetailsCOOL – Cooling Operation• To set the room temperature at your preferencecooling comfort.AUTO – Automatic Operation• Sense indoor temperature to select the optimummode.• Temperature is not displayed on the remote controlduring AUTO operation.DRY – Soft Dry Operation• A very gentle Cooling Operation, prior todehumidification. It does not lower the roomtemperature.• During Soft Dry operation, the indoor fan operates atLow fan speed.HEAT – Heating Operation(for Heat Pump Model only)• Heat is obtained from outdoor air to warm up theroom. When the outdoor ambient air temperaturefalls, the heating capacity of the unit might bereduced.• Defrosting OperationDepend on the outdoor temperature, the operationoccasionally stops to melt the frost on the outdoorunit.FAN – Air Circulation Operation(for Cooling Model only)• When the room temperature reaches the settemperature, operation commences at Low airflowvolume. It stops when the room temperature drops to2°C below the set temperature.(It is useful when using a heater). Setting the Fan Speed• Press 4 to select:-FAN – Low Fan SpeedFAN – Medium Fan SpeedFAN – High Fan SpeedAUTOFAN – Automatic Fan SpeedThe speed of the indoor fan is adjustedautomatically according to the operation.The indoor fan stops occasionally duringcooling operation. Setting the Vertical Airflow Direction• Press 5 or 6 to select:-Cooling Model Setting the Horizontal Airflow Direction Use this air conditioner under the followingconditions:Cooling Model• Adjust it manually Notes• If the unit is not going to be used for an extendedperiod of time, turn off the main power supply. If it isleft at the ON position, approximately 2.5 W ofelectricity will be used even if the indoor unit has beenturned off with the remote control.• If operation is stopped, then restart immediately, theunit will resume operation only after 3 minutes.Heat Pump ModelDBT: Dry Bulb TempWBT: Wet Bulb TempMaximum TemperatureMinimum TemperatureWBT2311DBT4316WBT2611Indoor OutdoorUnit in °CDBT3216DBT: Dry Bulb TempWBT: Wet Bulb TempMaximum Temperature-Cooling(Maximum Temperature-Heating)Minimum Temperature-Cooling(Minimum Temperature-Heating)DBT32(30)16(16)WBT23(-)11(-)DBT43(24)16(-5)WBT26(18)11(-6)Indoor OutdoorUnit in °C36°36° 61°COOL / DRY OperationAUTOFAN OperationAUTOSETTING THE TIMEREnsure that the current time is correct before setting thetimer. The timer cannot be set if the time display isflashing. ON-TIMER OperationTo start the air conditioner operation automatically.• Press 1 to set the operation.• Press 2 to increase or decrease the time.• Then press 3.• To cancel this operation, press 4. OFF-TIMER OperationTo stop the air conditioner operation automatically.• Press 5 to set the operation.• Press 2 to increase or decrease the time.• Then press 3.• To cancel this operation, press 4. Timer Mode Operation Details• When the ON-Timer is set, operation will startbefore the actual set time. This is to enable theroom temperature reaches the set temperature atthe set time.• Once the ON/OFF Timer is set, operation will start/stop at the set time everyday.• The current time is not displayed when the timersare set.• When both timers are used together, the TIMERmode indicator on the indoor unit remains lit evenwhen the operation is stopped by the OFF-TIMER.CONVENIENCE OPERATION Powerful Mode OperationTo obtain the set temperature quickly.• Press 6.* Powerful mode indicator (orange) on the indoorunit will light up.* Powerful mode will operate for 15 minutes only.• To cancel this operation, press once more. Powerful Mode Operation Details• The changes of the temperature and airflow volumeare automatic.• The remote control display remains unchanged.• If operation mode button is pressed, powerfuloperation will be cancelled.• During FAN – Air circulation operation, the powerfuloperation are not available.(cooling model only) Quiet Mode OperationTo provide quiet operation.• Press 7.* Quiet mode indicator on the indoor unit will lightup.• To cancel this operation, press once more. Operation Details• Air flow sound will reduce during operation. Ionizer Mode OperationProduce negative ion for fresh air.• Press 8.* Ion mode indicator on the indoor unit will light up.• To cancel this operation, press once more. Operation Details• Air conditioner ON:Provide negative ion during operation.• Air conditioner OFF:Provide negative ion with FAN operation.• If blinking, press 8 twice.If still blinking, please call service.CHECKAUTOAUTOHEAT DRY FANCOOLFANAUTORESET CLOCKMODE POWERFULQUIETFAN SPEEDAIR SWINGOFF CANCELON SET1 2 3TIMEROFF/ONAUTO MANUAL36417528AirflowvolumeSuper HighAutomaticPowerful ModeOperationCOOL / DRYHEAT(for Heat Pumpmodel only)Temperature3°C lowerthan set temp.3°C higherthan set temp.Heat Pump ModelCOOL,DRY, –>15 minutesin advanceHEAT, AUTO –>30 minutesin advanceCooling ModelCOOL,DRY, –>15 minutesAUTO in advance32CS-V7CKP CU-V7CKP5 / CS-V9CKP CU-V9CKP5 / CS-V12CKP CU-V12CKP5