6 PREVENTION OF STATIC ELECTRICITY DISCHARGEThe laser diode in the traverse unit (optical pickup) may brake down due to static electricity of clothes or human body. Use duecaution to electrostatic breakdown when servicing and handling the laser diode.6.1. Grounding for electrostatic breakdown preventionSome devices such as the DVD player use the optical pickup (laser diode) and the optical pickup will be damaged by staticelectricity in the working environment. Proceed servicing works under the working environment where grounding works iscompleted.6.1.1. Worktable grounding1. Put a conductive material (sheet) or iron sheet on the area where the optical pickup is placed, and ground the sheet.6.1.2. Human body grounding1. Use the anti-static wrist strap to discharge the static electricity form your body.6.1.3. Handling of optical pickup1. To keep the good quality of the optical pickup maintenance parts during transportation and before installation, the both ends ofthe laser diode are short-circuited. After replacing the parts with new ones, remove the short circuit according to the correctprocedure. (See this Technical Guide.)2. Do not use a tester to check the laser diode for the optical pickup. Failure to do so will damage the laser diode due to the powersupply in the tester.6.2. Handling Precautions for Traverse Unit (Optical Pickup)1. Do not give a considerable shock to the traverse unit (optical pickup) as it has an extremely high-precise structure.2. When replacing the optical pickup, install the flexible cable and cut its short land with a nipper. See the optical pickupreplacement procedure in this Technical Guide. Before replacing the traverse unit, remove the short pin for preventing staticelectricity and install a new unit. Connect the connector as short times as possible.3. The flexible cable may be cut off if an excessive force is applied to it. Use caution when handling the cable.4. The half-fixed resistor for laser power adjustment cannot be adjusted. Do not turn the resistor.9DVD-S325E / DVD-S325EG