– 7–4 –7.4. Test Equipment Setup7.4.1. Equipment RequiredFigure 7.5. : Test Connection DiagramIMPORTANT NOTETo allow accurate measurement of the complete unit the test equipment must be connected as shown,For testing the handheld unit the following equipment is required:1. PCB Repair Jig2. RF Adaptor3. RF Cable4. 12 V power supply5. Personal computer with RS232 interface and running Microsoft Windows® 95, 98, NT, XP or 20006. Data Cable7. GSM test station8. G60 Service softwareThe G60 Service software should be installed onto the main drive of the personal computer.The RF cable is connected to the GSM test station via suitable adaptor. The 3.8 V supply is connectedto the RF Adptor and PCB Repair Jig.NOTE: A suitable test SIM card compatible with the GSM test station will be required.PCB TEST SETUPCOMPLETE UNIT TEST SETUPT5 Screwdriver (Part No. )This screwdriver is required to remove the case screws from the phone.Data CableRF CablePCRFAdaptorGSM TesterHandset3.8 V DCPower SupplyData CableRF CablePCPCBGSM TesterPCBRepair Jig3.8 V DCPower SupplyCalibration SoftwareThis is the test software for the telephone unit and should be installed onto the personal computer to be used for testing.