Panasonic FD-F71 Instruction Manual
INSTRUCTION MANUALLeak Detection Fiber FD-F71MJEC-FDF71 No.0101-85VThank you very much for purchasing Panasonic prod-ucts. Read this Instruction Manual carefully and thor-oughly for the correct and optimum use of this product.Kindly keep this manual in a convenient place for quickreference.● For the mounting method to the amplifier, refer tothe Instruction Manual attached to the amplifier[FX-301(P)-F7],[FX-500 series].● For the method of mounting the fiber attachment(FX-AT4) and the method of using the fiber cutter,refer to the Instruction Manual (for general-purposefiber head) provided with the product.1 CAUTIONS● Do not scratch the sensing surface. If it is scratched,the detectability will deteriorate. When conductingmaintenance after operation, wipe all liquid from thesensor head and the mounting bracket with a softcloth. Further, take sufficient care against dew con-densation on the sensing surface.● The fiber cable can be cut for adjustment using theattached fiber cutter (FX-CT2), however, the sensingperformance may decrease depending on the cutcondition of the fiber cable and the connection to theamplifier.● If the intensity of incident light to the amplifier is satu-rated under no-liquid condition, perform saturationcorrection before using.● Take care not to scratch the fiber sheath while cut-ting the protective tube.● Make sure to use the exclusive mounting bracketwhen installing the sensor head to avoid human er-ror. Reliable detection cannot be guaranteed whenthis mounting bracket is not used. However, in casethe PVC mounting bracket is mounted on the darkand mat surface, human error may not be detected.Make sure to check it prior to use.● Make sure to adjust the sensitivity of the amplifier af-ter mounting the fiber head in the exclusive mountingbracket with no-liquid condition, completing layoutand wiring the fiber cable in actual working condi-tions. Changes in layout or installation after com-pleting sensitivity adjustment may result in the lossof reliable detection due to the change of incidentlight intensity.In case of re-mounting the fiber to the pipe or changein layout, adjust the sensitivity of the amplifier again.● Note that the light intensity may decrease when usedunder high temperature and high humidity for longperiod.● A liquid having poor affinity to the material of the sen-sor head (PFA) may create air bubbles, and if thoseare drawn in the sensing part, it takes some time forsensing to stabilize, or sensing may even becomeunstable.Make sure to check whether the sensing liquid hasan affinity ti the material of the fiber head.● Highly viscous liquid may not be detected stably.Liquid being detected should also be kept within therated ambient temperature range.2 MOUNTING● In case of using the SUS mounting bracket, in-sert the M4 stud-bolt (straight type) welded on thecustomer’s facilities into the mounting hole of themounting bracket and screw with M4 nut (please ar-range separately). The tightening torque should be0.98N·m or less.M4 stud-bolt(strait type)M4 nut● In case the PVC mounting bracket is used, face the‘TOP’ inscribed side up and use adhesive to stickfast the mounting bracket on the mounting surface.Make sure that the adhesive does not stick out fromthe fixable area as shown in the figure below.4mmFixable area11mm● Match the notch in the sensor body with the projec-tion of the exclusive mounting bracket and slide till aclick is felt.ProjectionNotch取 扱 説 明 書リークファイバ FD-F71このたびは、パナソニック製品をお買い上げいただき、ありがとうございます。ご使用の前にこの取扱説明書をよくお読みになり、正しく最適な方法でご使用ください。尚、この取扱説明書は大切に保管してください。● アンプへの装着方法については、アンプ[FX-301(P)-F7]、[FX-500 シリーズシリーズ]に付属の取扱説明書をご参照ください。● ファイバアタッチメント(FX-AT4)の装着方法、ファイバカッタの使用方法については、本製品に付属の取扱説明書(汎用ファイバヘッド)をご参照ください。1 注意事項● 検出部に傷を付けないでください。傷が付くと検出性能が低下します。メンテナンス時は、柔らかい布でヘッド部と取付具に付着した液体をすべて拭き取ってください。また、検出部の結露には、充分ご注意ください。● ファイバ部は、付属のファイバカッタ(FX-CT2)で自由に切断できますが、切断状態およびアンプの接続状態により、検出性能が低下するおそれがありますので、ご注意ください。● 液体のない状態でアンプの入光量が飽和している場合は、飽和補正をしてからご使用ください。● 保護チューブ切断時は、ファイバ外被に傷を付けないように切断してください。● 設置時は必ず、ヒューマンエラー(設置忘れなど)対策のため、専用取付具を使用してください。また、専用取付具を使用しない場合は、安定検出ができません。但し、筐体が黒っぽく光沢がない所に PVC 取付具を使用すると、ヒューマンエラー(設置忘れなど)が検出できない場合がありますので、ご使用前に必ず確認してください。● アンプの感度設定は、必ず液体のない状態でヘッド部を専用取付具に取り付け、ファイバ部を使用状態に配線、固定後行なってください。感度調整後、ファイバの配線または設置を変更すると入光量が変化し、安定検出ができません。メンテナンスなどでファイバの配線または設置を変更する場合も同様に、アンプの感度設定を行なってください。● 長期間高温 ・ 高湿状態で使用すると、光量が低下するおそれがありますのでご注意ください。● ヘッド部 - の材質(PFA 製)と親和性が悪い液体は、検出部に気泡を巻き込み、検出が安定するのに時間が掛かったり、不安定になる場合もありますのでご注意ください。ご使用の前には、必ず検出する液体で確認してください。● 高粘度の液体は、安定して検出できない場合があります。検出する液体の温度も使用周囲温度範囲内にしてください。2 取り付け● SUS 取付具を使用する場合、溶接してある M4 スタッドボルトを取付具の取付穴に差し込み、M4 ナット(別途ご用意ください)で取り付けます。そのときの締め付けトルクは、0.98N・m 以下としてください。M4ナットM4スタッドボルト(ストレートタイプ)● PVC 取付具を使用する場合は、“TOP”の刻印側を上面にして接合面に密着させて接着してください。また、下図の溶接範囲内にて溶接してください。4mm溶接範囲11mm● 筐体に取り付けた専用取付具の凸部とファイバの凹部を合わせ、“カチッ”と音がするまでスライドさせてください。凸部凹部Panasonic Industry Co., Ltd.1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japanhttps://industry.panasonic.com/Please visit our website for inquiries and about our sales network.Panasonic Industry Co., Ltd. 2024April, 2024 PRINTED IN JAPANパナソニック インダストリー株式会社〒571-8506 大阪府門真市大字門真1006番地https://industry.panasonic.com/<FAデバイス技術相談窓口>TEL:0120-394-205受付時間:平日の9時~12時、13時~17時(土日祝日、年末年始、当社休業日を除く)Panasonic Industry Co., Ltd. 20242024 年 4 月発行 PRINTED IN JAPAN |
Related manuals for Panasonic FD-F71
Panasonic FD-F8Y Instruction Manual
Panasonic FD-F41Y Instruction Manual
Panasonic ST4 Instruction Manual
Panasonic GD-3 Instruction Manual
Panasonic NA1-11 Instruction Manual
Panasonic HL-C211F Instruction Manual
Panasonic HL-C211B Instruction Manual
Panasonic HG-T1010 Instruction Manual
Panasonic HG-T1110 Instruction Manual
Panasonic SF4B-F23 V2 Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine