Panasonic FP2 Series Product Manual
Also see for FP2 Series: Programming manualManualTechnical manualTechnical manualUser manual
1SpecificationsFP2/FP2SHET-LAN unitsMulti-communication unitsPerformance SpecificationTransmission specifications for communication interface−−−−−−Start-stop synchronization−−−−RS232C RS485Note 1: The protocol can be downloaded from: www.panasonic-electric-works.comSpecificationsItemItem 100BASE-TXItemFP2-MWW modeToken busBase band500kbit/s 500kbit/s500kbit/s, 250kbit/sW2 mode 1) F modePollingItemVE mode (PLC link) FL-net modeModeCommunication methodTransmission methodTransmission speedTransmissiondistanceNumber ofExtendable to 800m250kbits/s: 1200m max.500kbits/s: 800m max.Extendable to 800m32 stations max.Extendable to 700mS-LINK unitsFP2-SL21128 points max.CPU unit with S-LINK portsFP2-C1SL2128 points max. × 2ItemNumber of channelsNumber of I/OpointsRated powersupply voltage* For FP2SH (Cannot be used for FP2)1)note 2) note 2)note 3)1)1)10BASE5 : 500m (2500m)10BASE-T : 100m (500m)FL-net [FA link protocol (UDP/IP)]MEWTOCOLCommunicationinterfaceCommunication speedCycle timeexampleCable lengthCommunication protocolLinkcommunicationspecificationsMessage communicationspecificationsNumber of nodesOther functionsEthernet10BASE5/10BASE-T10Mbit/s50ms/32 units(2048 points/2048 words)Link relay8192 points/unitLink register8192 words/unit2048 bytes max.(Compatible with MEWTOCOL)99 units max.Data transferRemote programmingMultilevel link communications1024 bytes max.(Not compatible with MEWTOCOL)254 units max.Interconnection with othercompanies' unitsCommunicationblock usedInterfaceCommunicationmethodSynchronizationTransmission lineTransmission distanceTransmission speed(To be set in the system register)Transmission codeTransmission format(To be set in the system register)Number of stationsPLC link capacityCOM1 (upper channel)COM2 (lower channel)Number of attachable unitsSupported versionsGeneral-purpose serial communications Computer link(Panasonic open protocol "MEWTOCOL" should be used.)1:1 communications 1:N communications 1:1 communications 1:N communicationsFP2-CB232FP2-CB422RS232C RS422Full duplexFP2-CB232FP2-CB422RS232C RS422Full duplexFP2-CB232FP2-CB422Three-core orfive-core shielded wire15m Length: 1200m max.300 to 230,400bpsTwisted-pair cableor VCTFLength: 1200m max.300 to 230,400bps(19,200 bps when our C-NET adapter is connected)99 stations max.(32 stations max. when our C-NET adapter is connected)−99 stations max.(32 stations max. when our C-NET adapter is connected)−16 stations max.Link relay: 1024 pointsLink register: 128 words−−Three-core orfive-core shielded wire15m Length: 1200m max.300 to 230,400bpsTwisted-pair cableor VCTFLength: 1200m max.300 to 230,400bps(19,200 bps when our C-NET adapter is connected)FP2-CB485RS485Two-wire half duplexFP2-CB485RS485Two-wire half duplexASCII, JIS7, JIS8, and binaryStart code: With STX / Without STXEnd code: CR/CR+LF/Time setting/ETXData length: 7 bits/8 bitsParity: 0/Invalid/Valid (Odd/Even)Stop bit: 1 bit/2 bits23 units max. (including 8 units for the computer link and 2 channels for the PLC link)CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or laterASCII, JIS7, JIS8PLC link functionTwisted-pair cableor VCTF1200m (RS485) 15m (RS232C)115,200bpsToken passing(Floating master)1 master +The number of input and output points for each channel can be selected by the switch in the unit bodyInput: 0/32/64/96/128 points Output: 0/32/64/96/128 points+24VDC ±10% Maximum allowable ripples (P-P): ±10%(S-LINK terminal block IN-24VDC 1.6 A or less)[Current consumption of the S-LINK controller (incl. D-G line current100Mbit/sBase band100m205m (2 segments)Category 5 UTP cable−−−100BASE-T10Mbit/sBase band100m500m (5 segments)Category 3, 4 and 5 UTP cable−−−100BASE510Mbit/sBase band500m2500m (5 segments)Transceiver cable50m100 nodes/segmentInteger multiples of 2.5mAAAAAAAAAN/AA: AvailableN/A: Not available* The lengths in parentheses areavailable when a repeater is used.Notes 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferritecore may be necessary in some cases, depending on the usage environment. Also, if the hub ispositioned close to a control board, we recommend using it at a distance of 10m or less.3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferritecore may be necessary in some cases, depending on the usage environment. Also, if the transceiver ispositioned close to a control board, we recommend using it at a distance of 5m or less.Communications functionNumber of communication connectionsTransparentcommunications bufferTransmitReceive- MEWTOCOL-COM: computer link function (max. 2KB)- MEWTOCOL-DAT: data transfer (max. 1020 words)- Transparent communication8 connections max.Factory setting: 1k words/connection x 3Factory setting: 1k words/connection x 3Transmission speedTransmission methodMax. segment lengthMax. distance between nodesCommunication cable or connectionMax. transceiver cablelengthMax. number of nodesNode spacingPerformance SpecificationTransmission specifications for communication interfaceSpecificationsItemItem 100BASE-TX 1)note 2) note 2)note 3)1)100Mbit/sBase band100m205m (2 segments)Category 5 UTP cable100BASE-T10Mbit/sBase band100m500m (5 segments)Category 3, 4 and 5 UTP cable100BASE510Mbit/sBase band500m2500m (5 segments)Transceiver cable50m100 nodes/segmentInteger multiples of 2.5mNotes: 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in somecases, depending on the usage environment. Also, if the hub is positioned close to a control board, we recommend using it at a distanceof 10m or less.3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in somecases, depending on the usage environment. Also, if the transceiver is positioned close to a control board, we recommend using it at adistance of 5m or less.Communications functionNumber of communication connectionsTransparentcommunications bufferTransmitReceive- MEWTOCOL-COM: computer link function (max. 2KB)- MEWTOCOL-DAT: data transfer (max. 1020 words)- Transparent communication8 connections max.Factory setting: 1k words/connection x 3Factory setting: 1k words/connection x 3Transmission speedTransmission methodMax. segment lengthMax. distance between nodesCommunication cable or connectionMax. transceiver cablelengthMax. number of nodesNode spacing09/2007 |
Related manuals for Panasonic FP2 Series
Panasonic FP7 Series User Manual
Panasonic FP2 Manual
Panasonic MN101L Series User Manual
Panasonic PanaXSeries MN1030 Series User Manual
Panasonic FP7 User Manual
Panasonic DLS6 Service Manual
Panasonic F77G User Manual
Panasonic TY-FB7HD Service Manual
Panasonic PanaXSeries MN103S65G User Manual
Panasonic TY-FB10HD Service Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine