Trace Operation and Time Chart5-105.3.3 Restrictions on Time Chart MonitorThe restrictions on the time chart are as follows. Although a maximum of 16 patterns of trace can be executed (in the case all LOGs areoperated for trace application), only one LOG can be displayed on the time chart. A maximum of 500 devices can be registered for one LOG, however, there are restrictionson devices to be graphically displayed on the time chart.・In case of contact device: According to the resolution of a display・In case of data devices: Up to six devices Time cannot be measured with the cursors (C, R) on graphs when the LOG displayed as atime chart is the data that was traced with logging triggers other than constant period.Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net