ADJUSTMENT PROCEDURESIssue 1 Section 7 MCUK010801C8Revision 0 – 38 – Service Manual7.2.2. GSM 18007.2.3 Power Level Calibration1. Power on the telephone in Test Set Mode.2. Scroll down the menu until CHANGE CH <62> is highlighted and then press ENTER.3. Scroll down the menu until PL <5> is highlighted. Use the left and right cursor keys to select <14>. Press ENTER.4. Scroll down the menu until TX DATA is highlighted. Using the left / right cursor keys, highlight and pressENTER.5. At the power meter, measure the peak power.6. If measured power is in the range of the target power, then proceed to step 10.Power Level(PL)Output Power (dBm)Change / dBNominal Target SpecMin Max Min Max0 29.05 28.8 29.3 28.8 29.3 31 27.8 27.3 28.3 27.0 28.8 3.52 26 25.5 26.5 25 27 43 24 23.5 24.5 23 25 4.54 22 21.5 22.5 21 23 4.55 20 19.5 20.5 19 21 4.56 1817.5 18.5 17 19 47 16 15.5 16.5 15 17 4814 13.5 14.5 13 15 49 12 11.5 12.5 11 13 410 10 9.5 10.5 9 11 411 87.5 8.5 7 9 412 6 5.5 6.5 5 7 413 4 3.5 4.5 3 5 414 2 1.5 2.5 1 3 415 0 -0.5 0.5 -1 1 4NOTE: To ensure that the telephone operates within set SAR margins, Panasonic recommends that a power metercapable of measurement to an accuracy of ±0.2 dB is used when calibrating power levels. Use of a lessaccurate power meter may result in the telephone failing to meet SAR standards.