INSTALLATION INSTRUCTIONSLong range laser distance sensorHG-F13A-A-□MJE-HGF1 No.0088-41VThank you for purchasing a Panasonic product.Read this Installation Instructions Manual carefully and follow them to install the prod-uct correctly and safely.Keep this manual in a safe location for reference whenever necessary.In this Installation Instructions Manual, safety precautions are classified into“WARNING” depending on the level of hazard.WARNINGIndicates that there is a risk of death or serious injuryWARNINGDo not use this product as a sensing device for personal protection. Using thisproduct as a sensing device for personal protection will result in death or seri-ous injury.For sensing devices for personal protection, use products that conform to thelaws and standards related to personal protection in each country, such asOSHA, ANSI, and IEC.This product is intended to be used to detect target objects and is not providedwith control functions that prevent accidents to ensure safety.Avoid observing beams in dark surroundings.Do not look at beams using an optical device such as an optical telephoto system.Never attempt to disassemble, repair, or modify this product.Control or adjustment according to procedures other than those provided in thisInstallation Instructions Manual and the separate User’s Manual may cause ex-posure to hazardous emitted laser beams.This manual provides a simple summary of installation procedures, etc.For details, refer to theHG-F1Series User’s Manual(our website: https://industrial.panasonic.com/ac/e/dl_center/manual/ ).1REGULATIONS AND STANDARDS●This product conforms to the standards and regulations below.EU Law: EMC Directive 2014/30/EUBritish Legislation : EMC Regulations 2016/1091‒Applicable StandardsEN 61000-6-4, EN 61000-6-2USA Regulation : FDA21 CFR 1040.10 and 1040.11 (Laser Notice No.56)USA / Canada Standards : UL 61010-1, CAN/CSA No.61010-1Other Standards: IEC 60825-1, JIS C 6802, GB 7247.1,KS C IEC 60825-1Note:When using this product in a region other than those listed above, be sure to check and com-ply with the regulations and standards applicable in the country or region where the productis used.2SAFE USE OF LASER PRODUCTIEC / JIS / GB / KS●To prevent laser products from affecting their users, IEC, JIS, GB, and KS haverespective standards.These standards classify laser products into classes according to the hazard levelof laser, and prescribe safety and preventive measures that should be implement-ed for each class.This product belongs to “Class 1 laser product” according to IEC 60825-1(JIS C6802, GB 7247.1,KS C IEC 60825-1) “Radiation Safety of Laser Products”.●Explanation of hazard levelsClassificationSummary of hazard evaluationClass 1A laser that is safe when operated under operating conditions that can be reasonably foreseen.Note:Pay attention to safety since hazardous laser beams may be emitted in the event of an unex-pected failure.●The following label is affixed to the side of this product based on the safety stan-dards for laser products.●Warning labelFDA●Exporting to the USAIf this product is incorporated into facilities or equipment to be exported to theUSA, it is subject to the laser regulations of the U.S. Food and Drug Administra-tion (FDA). To prevent laser products from affecting their users, PART1040 (Per-formance Standards for Light-Emitting Products) was established as one of theFDA regulations. These standards classify laser products into classes accordingto the hazard level of laser and prescribe safety and preventive measures thatshould be implemented for each class.This product complies with the FDA regulations (FDA 21 CFR 1040.10 and1040.11) in accordance with FDA Laser Notice No. 56, except for complying withIEC 60825-1 Ed. 3. (Class 1 Laser Product)When exporting this product to the USA, affix the FDA certificate / identificationlabel near the end of the cable.For details on standards, refer to theHG-F1 Series User’s Manual(our website: https://industrial.panasonic.com/ac/e/dl_center/manual/ ).●FDA certificate / identification label3CAUTIONSSpecifications●This product has been developed / produced for industrial use only.●Do not use this product outside the range of the specifications. Doing so will cause anaccident or product failure. There is also a risk of a noticeable reduction of service life.●There is a certain deviation in the directionality of this product. When using this product, installthe product using a mounting bracket or similar fitting to allow the adjustment of beam axis.●The internal memory (non-volatile memory) of this product has a service life. Set-tings cannot be configured more than one million times.●Leaked light exists around the detection point, and if an object with high reflec-tance is present around the detection point, this product may be affected by that.●If a regular reflection light enters the beam receiving window, proper measure-ment may not be possible. If the reflectance of the detected object is high, careful-ly select the installation location.Power Supply●Verify that the supply voltage fluctuations are within the rating when using theproduct. Note that applying a voltage greater than the rated voltage or directly ap-plying AC power will cause damage or burning.●To ensure performance, use the product at least 30 minutes (warm-up time) afterthe power is turned ON.●If power is supplied from a commercial switching regulator, ensure that the frameground (F.G.) terminal of the power supply is connected to an actual ground.●Make sure that the power supply input satisfies the following items.1)The power supply unit must be certified for use in your region.2)The power supply unit must have an output holding time of 20 ms or more.3)The power supply unit must have the rated output voltage of 24 V DC± 10%and the ripple (P-P) of 10% or less.4)The power supply unit must provide SELV (safety extra low voltage) or PELV(protective extra low voltage) confirming to the EMC Directive if the CE mark-ing compliance is required.5)The power supply unit must provide SELV (safety extra low voltage) or PELV(protective extra low voltage) confirming to the EMC Regulations if the UKCAmarking compliance is required.6)The power supply unit must support Class 2 ifCTÜVUSmarking compliance is required.●If surges occur, take countermeasures such as connecting a surge absorber tothe source of the surges.Wiring●Before wiring work always turn the power OFF.●Do not wire in parallel with a high-voltage line or power line, or run through thesame conduit. Doing so may result in malfunctioning due to induction.●Arrange the load to ensure that a current of 50 mA or higher does not flow to thecontrol output line. Also avoid incorrect wiring such as polarity connection error ofthe power supply. Failure to do so will cause damage or burning.●The overall length of the cable can be extended to 10m maximum with a cablesize of 0.3 mm2or more. Use a shielded cable to extend the analog line.●Do not apply stress such as excessive bending or pulling to the extracted part of a cable.Usage Environment●This product is suitable for indoor use only.●Do not install the sensor in the following locations.• Locations subject to flammable gas, corrosive gas, or excessive dust• Locations subject to dust, metal particles, or saline matter•Locations subject to benzine, paint thinner, alcohol or other organic solvents orstrong alkaline solutions such as ammonia or caustic soda• Locations subject to severe vibration or shock• Locations subject to direct sunlight• Locations subject to water, oil, or chemicals• Locations where load is applied to the sensor●Avoid using this product in environments where condensation occurs due to sud-den temperature change.●Performance may not be satisfactory in a strong electromagnetic field.●Take care that the sensor is not directly exposed to fluorescent lamp from a rap-id-starter lamp, a high frequency lighting device or sunlight etc., as it may affectthe sensing performance, although it depends on the type.●Keep the light emitting and receiving windows of this product clean and free ofwater, oil, fingerprints, and other substances that refract light as well as dust, grit,and other objects that intercept light. When cleaning the surfaces, wipe off con-taminants with a lint-free soft cloth or lens cleaning paper.●Make sure to turn OFF the power supply before cleaning the light emitting andreceiving windows of this product.●This product is a precision device. Do not drop or otherwise subject to shock. Do-ing so will cause product failure.●If a background object is present atthe specific regionshown below, a distancedifferent from the actual distance may be displayed owing to the sensing principle.Please check actual operation in the actual usage environment.031020304049(m)…242954Out of measurement rangeOut of measurement rangeSpecific regionSpecification measurement rangeIf there is any object in the specific region, block the laser beam within the rangeof less than 24 m.Other Matters●When this device becomes inoperable or unnecessary, dispose of the productproperly as industrial waste by abiding by the applicable law in the country.