Panasonic HL-C203F Instruction Manual
Also see for HL-C203F: User manualInstruction manual
5 CAUTIONSConnection● Turn off the power of controller before connecting or disconnecting the connectors.● When connecting or disconnecting the connectors, be sure to hold the connectorarea not to apply extra force to the cable.● Be careful not to touch terminals or to let foreign matter get in the connector afterdisconnecting connectors.● Be careful not to apply force to around the connector of standard cable and ex-tension cable. Do not bend the cables near connectors. Failure to do so causescauses disconnection of the cable.● When moving the sensor head during operation, install it so the cable not bendbend during movement. Use replaceable extensions cable in case the cableneeds bend.Wiring● Do not run the sensor cable along (bundled in parallel) with other wirings. Keep itat least 100mm away from other wires. Run the cable so it is separate from highvoltage and power circuit lines. If it is necessary to run the cable in parallel withthem, shield it by running through a grounded electrical conduit.● Install the product as far away as possible from noise source such as high-voltagelines, high-voltage device, power lines, power device, machines which generate alarge starting and stopping surge, welding machines and inverter motor.● Do not pull the cable using a force more than29.4N when routing the cable with the sen-sor head and controller fixed. At least 20 mmis required from the cable connection to thebend. The bending radius must be 30 mm ormore.● Use only 1 extension cable for connectionbetween one sensor head and a controller.20mm or moreR30mm or moreWarming up time● Allow at least 30 minutes of warming up after turning on the power to ensure theperformance of the product.Environment● The life of the semiconductor laser depends on the ambient temperature duringuse. When using the product near a heat source, take measures to lower the am-bient temperature of the sensor head as possible. Mount the sensor on a devicehaving good heat radiation because the sensor itself emits heat.● Water, oil, or fingerprints on the emitter surface and receiver surface of sensorhead reflects light. Dust and dirt on them block light. Keep them clean at all times.When cleaning these parts, wipe them off using a soft lint-free cloth or lens clean-ing paper.● Install the sensor head so ambient light such as sunlight or light with the samewavelength as laser beam should not enter the light receiver. If high accuracy isrequired, install a light shielding plate or the like on the sensor head.● The controller and connectors are not structurally dustproof, waterproof, or corro-sion-resistant. Do not use the product underwater or in the rain.● Do not use the product in dusty places or that exposed to flammable or corrosivegases, droplet, direct sunlight, severe vibration or impact.6 MEASUREMENT RANGE / INDICATOR● Installation Mode: DiffuseMeas. range indicator OFF Blink OFFBlinkONMeasurement rangeMeasurement centerdistance● Installation Mode: SpecularMeas. range indicator OFF Blink OFFBlinkONMeasurement rangeMeasurement centerdistance● The measurement range indicator at sampling cycle of 20μs or 10μs lights up atthe center of limited measurement range.7 MUTUAL INTERFERENCE AREA (Unit: mm)● When installing 2 or more sensor headsside by side, mutual interference occurs ifthe laser spots from other sensor heads fallwithin the shaded areas in the right figure.Install sensor heads so the laser spots fromother sensor heads fall outside the shadedareas.8 BEAM DIAMETER (Unit: mm)0.22 0.03 0.220.85 1.2 1.550.180.180.030.030.180.18HL-C203F(E)Minimal spot typeHL-C203F(E)-MKLine spot typeMeasurement rangeMeasurement center distance9 DIMENSIONS (Unit: mm)● Installation Mode: DiffuseBeam Attenuator(Measurement center distance)Lightemission axisLightreception axis2-M5 mounting holeDepth:10(opposite surface)Measurementrange indicator(yellow)Laser emissionindicator(green)● Installation Mode: SpecularBeam AttenuatorSpecular reflection lineThe reference surface for specular reflection installation(Measurement center distance)Light emission axisLight reception axis10 OPTION● ND filter (product code: HL-C2F01) is optionally available to adjust the excessivereceived light intensity to an optimum level. This is useful when mounting the sen-sor head for specular reflection.http://panasonic.net/id/pidsx/globalOverseas Sales Division (Head Office)2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, JapanPhone: +81-568-33-7861 FAX: +81-568-33-8591About our sale network, please visit our website.PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2013 |
Related manuals for Panasonic HL-C203F
Panasonic HL-C203F-MK Instruction Manual
Panasonic HL-C203B Instruction Manual
Panasonic HL-C201F Instruction Manual
Panasonic HL-C201A Instruction Manual
Panasonic HL-C211F Instruction Manual
Panasonic HL-C211F5 Instruction Manual
Panasonic HL-C235BE Instruction Manual
Panasonic HL-C211BE Instruction Manual
Panasonic HL-C201A-SP3 Instruction Manual
Panasonic HL-C211F-MK Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine