2 FOR SERVICE TECHNICIANSICs and LSIs are vulnerable to static electricity.When repairing, the following precautions will help prevent recurring malfunctions.1. Cover the plastic parts boxes with aluminum foil.2. Ground the soldering irons.3. Use a conductive mat on the worktable.4. Do not touch IC or LSI pins with bare fingers.3 CAUTION3.1. NOTEWhen you note the serial number, write down all of the 11 digits.The serial number may be found on the label affixed to the bottom of the unit.3.2. SAFETY PRECAUTIONS1. Before servicing, unplug the power cord to prevent an electric shock.2. When replacing parts, use only the manufacturer´s recommended components for safety.3. Check the condition of the power cord. Replace if wear or damage is evident.4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to preventthe customer from being exposed to shock hazards.3.3. INSULATION RESISTANCE TEST1. Unplug the power cord and short the two prongs of the plug with a jumper wire.2. Turn on the power switch.3. Measure the resistance value with ohmmeter between the jumpered AC plug and each exposed metal cabinet part, such asscrew threads, control shafts, handle brackets, etc.Note:Some exposed parts may be isolated from the chassis by design. These will read infinity.4. If the measurement is outside the specified limits, there is a possibility of shock hazard. The equipment should be repaired andrechecked before it is returned to the customer.3.4. BATTERY CAUTION1. Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by themanufacturer. Dispose of used batteries according to the manufacturer’s Instructions.2. The lithium battery is a critical component (type No.CR23541). Please observe for the proper polarity and the exact locationwhen replacing it and soldering the replacement lithium battery in.3.5. CAUTIONThe power socket wall outlet should be located near this equipment and be easily accessible.5KX-TDA600BX