51KX-TG4021LAT/KX-TG4022LAT/KX-TG4023LAT/KX-TGA403LAT12.3. Adjustment Standard (Base Unit)When connecting the simulator equipment for checking, please refer to below.12.3.1. Bottom ViewNote:(*1) is referred to No.2 of Check Check Table for RF part (P.39)(*2) is referred to Power Supply Circuit/Reset Circuit (P.12)CL2C477C478SPP SPNC530C321DCDC_OUTC322C476 FCTRSTNSTM/CKM/P15C343C511C510C165C163C351CHARGE+ CHARGE-C514C181C171C121C122C152C125C112C352ANT2CL1R502RTCKR322R321R302R605R606R612R335R602R603R112R178VCCA VREFR166R164R161R136VDDCR151R152R115R121L371L1T L1RL476L474L372L362IC601 IC302IC611RA151RA504D361D473 D472D153D133D363Q161Q601C142C513C167C512C186C184C601 C479C307C301C332C521C133C123C472C473C475C120C124C151C525C524C611C115C168C126C661R165F301DCP DCMR512R507R307R607R601R304 R305R301R505R506R334R604R181R162R503R167R163R122L361RA502D142D143CHG+2 CHG-2B+6.5VRTCKE443581+3.0VVBATTMSTCKTDITDOVBGGND UTX URX3.0AANT1PNLB1712ZPbFCHGSPDCREDREDREDWHTBLKBLKYLWGRNSpectrum AnalyzerFrequency Counter (*1)Oscilloscope8VoltMeterDC6.5VOscilloscope (*2)* Send command "SFR", thenthe frequency output on this TP.* Start Monitor