41KX-TG4131MEB/KX-TG4132MEB/KX-TG4133MEB/KX-TGA410MEB10.1.6.3. Check Table for RF partNote:(*1) Refer to Commands (Handset) (P.55)(*2) Refer to Commands (Base Unit) (P.55)(*3) Adjustment Standard (Base Unit) (P.56)(*4) Adjustment Standard (Handset) (P.58)No. Item BU (Base Unit) Check HS (Handset) Check1 Link Confirmation NormalHS, BU Mode [Normal Mode]1. Register Regular HS to BU (to bechecked).2. Press [Talk] key of the Regular HS toestablish link.1. Register HS (to be checked) to RegularBU.2. Press [Talk] key of the HS to establish link.2 X 'tal Frequency confirmationHS, BU Mode: [Adjustment]Check X' tal Frequency.(10.368 MHz ±100Hz)Check X 'tal Frequency.(13.824 MHz ±100 Hz)3 TX confirmationHS Mode:HS_Burst Mode] (*1)BS Mode:BS_Burst Mode] (*2)1. Remove wire antenna 2 and connectspectrum analyzer to TP. (*3).2. Confirm TX power whether spec. issatisfied.Power >=14.5dBm1. Connect spectrum analyzer to TP.(*4)2. Confirm TX power whether satisfied spec.Power >=16.0dBm4 Range Confirmation NormalHS, BU Mode: [Normal Mode]1. Register Regular HS to BU (to bechecked).2. Press [Talk] key of the Regular HS toestablish link.3. Compare the range of the BU (beingchecked) with that of the Regular BU.1. Register HS (to be checked) to RegularBU.2. Press [Talk] key of the HS to establish link.3. Compare the range of the HS (beingchecked) with that of the Regular HS.